3. Door opening sensing circuit
✽
Since door switch sensing switch (A), (B) are a separate switch even if the door switch of the freezing room normally
operates, they may fail to sense door opening in the failure of switch at both ends of (A) and (B) or in failure of the L/wire.
✽
Lamp does at the cold storage room not turn on if the door switch of the cold storage room fails to sense the door open
switch (c ), (d) or the home bar switch.
EXPLATION FOR MICOM CIRCUIT
- 37 -
Closing
5 V ( A - B , C - D . S/W at both ends are at Off status)
Opening
5 V ( A - B , C - D . S/W at both ends are at On status)
Measuring part
IC1 (MICOM) No. 47, 46 Pin
Door of Freezing/Cold Storage Room
<GR-L207, GR-L247> <GR-B197, GR-B207, GR-B247>
<GR-L207, GR-L247> <GR-B197, GR-B207, GR-B247>
CONDITIONS
Bell sounds when button on
Beep sounds when warning
MEASURING
dosplay is pressed.
door opening.
OFF
POINTS
IC1 (No. 48 Pin)
5 V
IC1 (No. 51 Pin)
0 V
0.05 s
2.63 kz (DING)
2.63 kz (BEEP)
OFF
2.21 kz (DONG)
0.2 s
0.1 s
0.4 s
0.5 s
0.5 s
5 V
0 V
5 V
0 V
5 V
0 V
5 V
0 V
Summary of Contents for GR-B197DVCA
Page 43: ...2 GR B197 GR B207 GR B247 EXPLATION FOR MICOM CIRCUIT 43 ...
Page 49: ...2 GR B197 GR B207 GR B247 EXPLATION FOR MICOM CIRCUIT 49 ...
Page 50: ...3 2 Parts list 1 GR L207 GR L247 EXPLATION FOR MICOM CIRCUIT 50 ...
Page 51: ...EXPLATION FOR MICOM CIRCUIT 51 ...
Page 52: ...2 GR B197 GR B207 GR B247 EXPLATION FOR MICOM CIRCUIT 52 ...
Page 53: ...EXPLATION FOR MICOM CIRCUIT 53 ...
Page 55: ...EXPLATION FOR MICOM CIRCUIT 55 ...
Page 56: ...2 GR B197 GR B207 GR B247 EXPLATION FOR MICOM CIRCUIT 56 ...
Page 57: ...EXPLATION FOR MICOM CIRCUIT 57 ...
Page 64: ...CIRCUIT 64 ...
Page 65: ...CIRCUIT 65 ...