![LG GR-562 Service Manual Download Page 22](http://html.mh-extra.com/html/lg/gr-562/gr-562_service-manual_1902595022.webp)
7-1-5 ERROR DIAGNOSTIC MODE
1. The error diagnostic mode allows the SVC when a fault that may affect the performance of the product occurs while
operating the product.
2. Even if the function control button is pushed when an error occurs, the function will not be performed.
3. When the error is cleared while the error code is displayed due to a fault, the appliance returns to the normal condition
(Reset).
4. The error code is displayed by the refrigerator temp indication LED on the display of the refrigerator while the remaining
LEDs are off.
- 22 -
GR-R562/R602
GR-S562/S602
R1
R2
R3
R4
NO
Error
Error Code Display
Cause
State of Operation with Error
R1 R2 R3 R4
Comp / Cooling fan Defrosting heater
: ON
: OFF
1.
2.
3.
Faulty refrigerator(R)
sensor (on the control
box of the refrigerator)
Faulty defrosting sensor
Defrosting failure
Cut or short-circuited wire of
refrigerator sensor
Cut or short-circuited wire of
defrosting sensor
Cut or disconnected wire of
defrosting heater or temperature
fuse(indicated at least 2 hours
later after the error occurs)
15 min ON/
15 min OFF
No defrosting
Summary of Contents for GR-562
Page 32: ...7 5 MAIN PWB ASS Y AND PARTS LIST 7 5 1 MAIN PWB ASS Y 32 u u GR R562 R602 ...
Page 33: ...7 5 2 MAIN PWB ASS Y 33 u u GR S562 S602 ...
Page 34: ...7 5 3 REPLACEMENT PARTS LIST u u GR R562 R602 34 ...
Page 35: ...7 5 4 REPLACEMENT PARTS LIST u u GR S562 S602 35 ...
Page 36: ...7 5 5 PWB ASS Y DISPLAY AND PARTS LIST u u GR R562 R602 36 ...
Page 37: ...7 5 6 PWB ASS Y DISPLAY AND PARTS LIST u u GR S562 S602 37 ...
Page 38: ...7 6 1 PWB DIAGRAM u u GR R562 R602 38 ...
Page 39: ... 39 ...
Page 40: ...7 6 2 PWB DIAGRAM u u GR S562 S602 40 ...
Page 41: ... 41 ...