¥ TEMPERATURE COMPENSATION OF FREEZER ROOM
¥ This circuit is aimed to input the necessary temperature compensation values into the MICOM in order to adjust the freezer
temperature which is different in each model.
- 26 -
Revised resistance
470½
2k½
3.3k½
5.6k½
8.2k½
10k½
12k½
18k½
33k½
56k½
180k½
Present resistance
NOT
1¡C
↑
2¡C
↑
3¡C
↑
4¡C
↑
5¡C
↑
6¡C
↑
7¡C
↑
8¡C
↑
9¡C
↑
10¡C
↑
470½
COMPENSATE
1¡C
↓
NOT
1¡C
↑
2¡C
↑
3¡C
↑
4¡C
↑
5¡C
↑
6¡C
↑
7¡C
↑
8¡C
↑
9¡C
↑
2k½
COMPENSATE
2¡C
↓
1¡C
↓
NOT
1¡C
↑
2¡C
↑
3¡C
↑
4¡C
↑
5¡C
↑
6¡C
↑
7¡C
↑
8¡C
↑
3.3k½
COMPENSATE
3¡C
↓
2¡C
↓
1¡C
↓
NOT
1¡C
↑
2¡C
↑
3¡C
↑
4¡C
↑
5¡C
↑
6¡C
↑
7¡C
↑
5.6k½
COMPENSATE
4¡C
↓
3¡C
↓
2¡C
↓
1¡C
↓
NOT
1¡C
↑
2¡C
↑
3¡C
↑
4¡C
↑
5¡C
↑
6¡C
↑
8.2k½
COMPENSATE
FREEZER
5¡C
↓
4¡C
↓
3¡C
↓
2¡C
↓
1¡C
↓
NOT
1¡C
↑
2¡C
↑
3¡C
↑
4¡C
↑
5¡C
↑
ROOM
10k½
COMPENSATE
(R1)
6¡C
↓
5¡C
↓
4¡C
↓
3¡C
↓
2¡C
↓
1¡C
↓
NOT
1¡C
↑
2¡C
↑
3¡C
↑
4¡C
↑
12k½
COMPENSATE
7¡C
↓
6¡C
↓
5¡C
↓
4¡C
↓
3¡C
↓
2¡C
↓
1¡C
↓
NOT
1¡C
↑
2¡C
↑
3¡C
↑
18k½
COMPENSATE
8¡C
↓
7¡C
↓
6¡C
↓
5¡C
↓
4¡C
↓
3¡C
↓
2¡C
↓
1¡C
↓
NOT
1¡C
↑
2¡C
↑
33k½
COMPENSATE
9¡C
↓
8¡C
↓
7¡C
↓
6¡C
↓
5¡C
↓
4¡C
↓
3¡C
↓
2¡C
↓
1¡C
↓
NOT
1¡C
↑
56k½
COMPENSATE
10C
↓
9¡C
↓
8¡C
↓
7¡C
↓
6¡C
↓
5¡C
↓
4¡C
↓
3¡C
↓
2¡C
↓
1¡C
↓
NOT
180k½
COMPENSATE