The following description is basically for GR-S462/GR-S512. For the other models, refer to the diagram of the entire PCB
circuit.
7-1 FUNCTION
7-1-1 FUNCTION
1. When the appliance is plugged in, it is set to ‘Medium’. Each time the button is pushed, it is set to
‘Medium’
→
‘Medium/High’
→
‘High’
→
‘Low’
→
‘Medium/Low’
→
‘Medium’ in order.
2. When the power is initially applied or restored after a power failure, it is automatically set to ‘Medium’.
7. DESCRIPTION OF FUNCTION & CIRCUIT OF MICOM
- 16 -
Temp
Control
Medium/
Medium/
Low
Low
Medium
High
High
TEMP(˚C)
7
4
2
0
-2
ROOM
REFRIGERATOR