- 17 -
NO.
ITEMS
CONTENTS AND SPECIFICATIONS
REMARKS
WELDING
(1) H 30
ROD
(1)
• Chemical Ingredients
• Recommend H34 containing 34% Ag in the
(1) •
Ag: 30%, Cu: 27%, Zn: 23%, Cd: 20%
•
Service Center.
(1)
• Brazing Temperature: 710~840°C
(2) Bcup-2
(1)
• Chemical Ingredients
(1) •
Cu: About 93%
(1) •
P: 6.8~7.5%
(1) •
The rest: within 0.2%
(1)
• Brazing Temperature: 735~840°C
FLUX
(1)
• Ingredients and how to make
• Make amount for only a day.
( 1 )
(1) ••
Borax 30%
•
Holding period: 1 day
(1) ••
Borax 35%
• Close the cover of container to prevent dust
(1) •
Fluoridation kalium: 35%
•
putting in the FLUX.
(1) •
Water: 4%
• Keep it in a stainless steel container.
(1) •
Mix the above ingredients and boil until
(1) •
they are transformed into liquid.
DRIER
(1) Assemble the drier within 30min.
• Don't keep the drier in a outdoor because
ASM
(1)
after unpacking.
•
humidity damages to it.
(2) Keep the unpacked drier at the temperature
of 80~100°C.
VACUUM
(1) When measuring with pirant Vacuum
• Apply M/C Vacuum Gauge without fail.
(1 )
gauge of charging M/C, vacuum
• Perform vacuum operation until a proper
(1 )
degree is within 1 Torr.
•
vacuum degree is built up.
(2) If the vacuum degree of the cycle inside is
• If a proper vacuum degree isn't built up,
•
(2)
10 Torr. below for low pressure and 20 Torr.
•
check the leakage from
(2)
for high pressure, it says no vacuum
•
the Cycle Pipe line part and
(2)
leakage state.
•
Quick Coupler Connecting part.
(3) Vacuum degree of vacuum pump must be
(3)
0.05 Torr. below after 5 min.
(4) Vacuum degree must be same to the
value described item (2) above for more than
20 min.
(1) The pressure of dry air must be more
than 12~16Kg/cm
2
(2) Temperature must be more than
-20~-70°C.
(3) Keep the pressure to 12~6Kg/cm
2
also
(3)
when substituting dry air for Nitrogen Gas.
NIPPLE
(1) Check if gas leaks with soapy water.
• Check if gas leaks from connecting part of
AND
(2) Replace Quick Coupler in case of leakage.
•
Coupler.
COUPLER
PIPE
(1)
• Put all Joint Pipe in a clean box and
(1)•
cover tightly with the lid so that dust or
(1)•
humidity is not inserted.
1
2
3
4
5
6
7
DRY AND
AIR
NITROGEN
GAS
▼
General Control of Refrigerating Cycle
Summary of Contents for GN-B492Y*C
Page 35: ...7 5 2 REPLACEMENT PARTS LIST 35 ...
Page 36: ... 36 ...
Page 37: ...7 5 3 PWB ASS Y DISPLAY AND PARTS LIST 37 ...
Page 38: ... 38 7 5 4 PWB ASS Y DISPLAY I MICOM AND PARTS LIST ...
Page 39: ... 39 7 5 5 V LED DISPLAY PART LIST ...
Page 40: ...7 6 PWB DIAGRAM 40 ...
Page 41: ... 41 ...
Page 48: ... 48 265K 267C 267J 267K 267D 267B 267H 267F 267G 267E 265J 267A 255A 265L 264M u GN M492Y Y ...
Page 49: ......