background image

Owner’s Manual  11

ENGLISH

Power

button

Open the front
panel upward

Operating Instructions

Vertical Airflow Direction Control

The up/down airflow (Vertical Airflow) can be adjusted
by using the remote control.

1. Press the Start/Stop button to start the unit.
2. Press Chaos Swing button and the louvers will swing

up and down. Press the Chaos Swing button again
to set the vertical louver at the desired airflow
direction.

❏ 

If you press the CHAOS swing button, the
horizontal airflow direction is changed
automatically based on the CHAOS algorithm to
distribute the air in the room evenly and at the
same time to make the human body feel most
comfortable, as if enjoying a natural breeze.

❏ 

Always use the remote control to adjust the
up/down airflow direction. Manually moving the
vertical airflow direction louver by hand, could
damage the air conditioner.

❏ 

When the unit is shut off, the up/down airflow
direction louver will close the air outlet vent of the
system.

NOTICE

Horizontal Airflow Direction Control

• Adjust the horizontal airflow direction by manually moving the

horizontal airflow direction louver by hand.

Operation procedures when the remote control can't be used.
The operation will be started if the power button is pressed.
If you want to stop operation, re-press the button.

Forced Operation

Heat pump Model

Cooling

Model

Room Temp.

 ≥ 

24

°

C 21

°

≤ 

Room Temp. < 24

°

C

 

Room Temp. < 21

°

C

Operating mode

Cooling

Cooling

Healthy Dehumidification

Heating

Indoor FAN Speed

High

High

High

High

Setting Temperature

22

°

C

22

°

C

23

°

C

24

°

C

Test operation

During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room
temperature and resets in 18 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller sets.
If you want to use this operation, open the front panel upward and Press the power button let it be pressed
for about 3 seconds.
If you want to stop the operation, re-press the button.

Summary of Contents for G122C SR2

Page 1: ...g and operating your room air conditioner Please retain this owner s manual for future reference after reading it thoroughly ENGLISH Dear Owner Thank you for installing LG air conditioner Your best choice guarantees you a great performance and service to make your life comfortable pleasant MODELS G122C SR2 G182C ST2 G182C ST3 G242C ST2 P No 3828A20402W ESPAÑOL ...

Page 2: ...ems in the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all PRECAUTION Contact the authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should b...

Page 3: ...nspecified power cord It will cause electric shock or fire In the supply cord is damaged it mut be replaced by the manufacturer or its service agent or a similarly quallfied person in order to avoid a hazard Y Attachment Do not modify power cord length or share the outlet with other appliances It will cause electric shock or fire due to heat generation Do not operate with wet hands or in damp envi...

Page 4: ...ables precision machine or conservation of art articles It may cause damage of animals or vegetables or loss of property Stop operation and close the window in storm or hurricane Operation with windows opened may cause wetting of indoor and soaking of household furniture Hold the plug by the head of the power plug when taking it out It may cause electric shock and damage Turn off the main power sw...

Page 5: ...preserving precision devices food pets plants and art objects Such usage could damage the items 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock 3 When cleaning the unit first make sure that the ...

Page 6: ...stored mounted on a wall To operate the room air conditioner aim the remote control at the signal receptor Storage and Tips For Using the Remote Control Signal Receptor Receives the signals from the remote controller Signal receiving sound two short beeps or one long beep Operation Indication Lamps On Off Lights up during the system operation Defrost Mode Lights up during Defrost Mode or Hot Start...

Page 7: ...ment and set the desired up down airflow direction OPERATION MODE SELECTION BUTTON Used to select the operation mode OFF TIMER BUTTON Used to set the time of stopping operation START STOP BUTTON Operation starts when this button is pressed and stops when the button is pressed again ROOM TEMPERATURE SETTING BUTTONS INDOOR FAN SPEED SELECTION BUTTON JET COOL Used to start or stop the speed cooling S...

Page 8: ... 2 3 4 Natural wind by the CHAOS logic For more fresh feeling than other fan speed press the Indoor Fan Speed Selector and set to CHAOS mode In this mode the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic Healthy Dehumidification Operation Mode This mode dehumidifies without overcooling During Healthy Dehumidification Operation If you select the deh...

Page 9: ...1 hour to 7 hours Timer control Setting OFF TIMER CONTROL SETTING Press the Start Stop button The unit will respond with a beep To select Heating Operation press the Operation Mode Selection button Each time the button is pressed the operation mode is shifted in the direction of the arrow Set the temperature higher than the room temperature The temperature can be set within a range of 16 C 30 C in...

Page 10: ...he normal cooling mode from the JET COOL mode you just press either the operation mode selection button airflow volume selection or temp setting button or the JET COOL button again NOTICE Press the Start Stop button The unit will respond with a beep Press the Jet Cool button to operate the speed cooling mode and the unit will operate in super high fan speed on cooling mode for 30 minutes To cancel...

Page 11: ... up down airflow direction louver will close the air outlet vent of the system NOTICE Horizontal Airflow Direction Control Adjust the horizontal airflow direction by manually moving the horizontal airflow direction louver by hand Operation procedures when the remote control can t be used The operation will be started if the power button is pressed If you want to stop operation re press the button ...

Page 12: ...he front grille should be checked and cleaned once every 2 weeks or more often if neccessary Never use any of the followings Water hotter than 40 C Could cause deformation and or discoloration Volatile substances Could damage the surfaces of the air conditioner Lift the front access panel and pull the filter tab slightly forward to remove the filter Clean the filter with a vacuum or warm soapy wat...

Page 13: ...t of the indoor outdoor unit are not blocked Do not overcool the room This is not good for the health and wastes electricity Make sure that the doors and windows are shut tight Avoid opening doors and windows as much as possible to keep the cool air in the room Keep blinds or curtains closed Do not let direct sunshine enter the room when the air conditioner is in operation Clean the air filter reg...

Page 14: ...a damp smell exuded by the walls carpet furniture or cloth items in the room Condensation occurs when the airflow from the air conditioner cools the warm room air This is the protector of the mechanism Wait about three minutes and operation will begin Is the air filter dirty See air filter cleaning instructions Has the temperature been set incorrectly Are the indoor unit s air inlet or outlet vent...

Page 15: ...Impreso en Corea LG ELECTRONICS MEXICO S A DE C V Sor Juana Ines de la Cruz No 555 San Lorenzo Tlalnepantla Estado de Mexico C P 54033 TEL 55 5321 1994 01800 3471919 ...

Reviews: