background image

Owner's Manual 

11

TIME

OFF

hr.

TEMP.

TIME

OFF

hr.

TIME

OFF

hr.

TEMP.

TIME

OFF

hr.

TEMP.

Cooling

Healthy

Dehumidification

Heating

(Heat pump model only)

TEMP.

TIME

OFF

hr.

TIME

OFF

hr.

TEMP.

Cooling

Healthy

Dehumidification

Bee

p, B

eep

Beep, Beep

Operating Instructions

ENGLISH

Healthy Dehumidification Operation Mode

Press the Start/Stop Button.

Select Healthy Dehumidification Operation.
Press the Operation Mode Selection Button.
Each time the button is pressed, the operation mode is shifted
in the arrow direction.

You can select the fan speed in four
steps-low, medium, high, or CHAOS.
Each time the button is pressed, the fan
speed mode is shifted.

1

2

3

This mode dehumidifies without overcooling.

During Healthy Dehumidification Operation:

o

If you select the dehumidification mode on the operation selection button, the airconditioner starts to run the
dehumidification function, automatically setting the room temp. and airflow volume to the best condition for
dehumidification based on the sensed current room temp.

In this case, however, the setting temp. is not displayed in the remote control and you are not able to control the
room temp. either.

o

During the healthy dehumidification function, the airflow volume is automatically set according to the
optimization algorithm responding to the current room temp. status and makes the room condition healthy and
comfortable even in the high humidity season.

Summary of Contents for G09LHK

Page 1: ... and retain it for future reference WALL MOUNTED OWNER S MANUAL AIR CONDITIONER The equipment complies with requirements of the Technical Regulation in terms of restrictions for the use of certain dangerous substances in electrical and electronic equipment ENGLISH РУССКИЙ ЯЗЫК O ZBEK TILI ...

Page 2: ...nstallation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to ensure that they do not play with the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts A Safety Precautions 3 B Electrical Safety 6 Tem...

Page 3: ... securely There is risk of fire or electric shock due to dust water etc Use the correctly rated breaker or fuse There is risk of fire or electric shock Do not modify or extend the power cable If the power cable or cord has scrathes or skin peeled off or deteriorated then it must be replaced There is risk of fire or electric shock For installation removal or reinstall always contact the dealer or a...

Page 4: ...ric shock Do not allow water to run into electric parts Install the unit away from water sources There is risk of fire failure of the product or electric shock Do not store or use or even allow flammable gas or combustibles near the product There is risk of fire Do not use the product in a tightly closed space for a long time Perform ventilation regularly Oxygen deficiency could occur and hence ha...

Page 5: ...y If the refrigerant gas leaks during the installation ventilate the area immediately Otherwise it can be harmfull for your health Dismantling the unit treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards Replace the all batteries in the remote control with new ones of the same type Do not mix old and new batteries or different types of...

Page 6: ...nuine adapter available from most local hardware stores Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection To disconnect the power cord from the adapter use one hand on each to avoid damaging the ground terminal Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage Never use the applia...

Page 7: ...o restart setting Timer Defrost mode Lights up during defrost mode or hot start operation Heat pump model only Lights up during outdoor unit operation Cooling model only Outdoor unit operation OUT DOOR Hot start operation Stops the indoor fan in heating operation for minutes to prevent cold air from blowing out from unit In defrost mode unit stops heating operation for few minutes to remove format...

Page 8: ...h of the batteries 4 Use 2 AAA 1 5volt batteries NOTE 1 Choose a suitable place where its safe easy to reach 2 Fix the holder to wall etc with the supplied screws firmly 3 Slide the remote controller inside the holder 1 Remote controller should never be exposed to direct sunlight 2 Signal transmitter receiver should always be clean for proper communication Use a soft cloth to clean them 3 In case ...

Page 9: ...ment and set the desired up down airflow direction OPERATION MODE SELECTION BUTTON Used to select the operation mode OFF TIMER BUTTON Used to set the time of stopping operation START STOP BUTTON Operation starts when this button is pressed and stops when the button is pressed again ROOM TEMPERATURE SETTING BUTTONS INDOOR FAN SPEED SELECTION BUTTON JET COOL Used to start or stop the speed cooling S...

Page 10: ...ach time the button is pressed the operation mode is shifted in the arrow direction Set the temperature lower than the room temperature The temperature can be set within a range of 18 C 30 C by 1 C Set the fan speed Select the fan speed in four steps low medium high or CHAOS Each time the button is pressed the fan speed mode is shifted The display shows high fan speed Cooling Operation 1 2 3 4 Nat...

Page 11: ... pressed the fan speed mode is shifted 1 2 3 This mode dehumidifies without overcooling During Healthy Dehumidification Operation o If you select the dehumidification mode on the operation selection button the airconditioner starts to run the dehumidification function automatically setting the room temp and airflow volume to the best condition for dehumidification based on the sensed current room ...

Page 12: ...1 hour to 7 hours Timer control Setting OFF TIMER CONTROL SETTING Press the Start Stop button The unit will respond with a beep To select Heating Operation press the Operation Mode Selection button Each time the button is pressed the operation mode is shifted in the direction of the arrow Set the temperature higher than the room temperature The temperature can be set within a range of 16 C 30 C in...

Page 13: ...to the normal cooling mode from the JET COOL mode you just press either the operation mode selection button airflow volume selection or temp setting button or the JET COOL button again NOTE Press the Start Stop button The unit will respond with a beep Press the Jet Cool button to operate the speed cooling mode and the unit will operate in super high fan speed on cooling mode for 30 minutes To canc...

Page 14: ...Cooling Cooling Healthy Dehumidification Heating Indoor FAN Speed High High High High Setting Temperature 22 C 22 C 23 C 24 C Test operation During the TEST OPERATION the unit operates in cooling mode at high speed fan regardless of room temperature and resets in 18 minutes During test operation if remote controller signal is received the unit operates as remote controller sets If you want to use ...

Page 15: ... to distribute the air in the room evenly and at the same time to make the human body feel most comfortable as if enjoying natural breeze Always use the remote controller to adjust the up and down air flow direction Manually moving the vertical air flow direction louver by hand could damage the mechanism When the unit is shut off the up down airflow direction louver will close the air outlet vent ...

Page 16: ...ce in every 2 weeks or more often if necessary To remove the filters see the self explanatory diagrams for each model type Clean the filters with a vacuum cleaner or warm soapy water If dirt is not easily removed wash with a solution of detergent in luke warm water Dry well in shade after washing and reinstall the filters back in place Removal of Filters Open the front panel as shown Then pull the...

Page 17: ...Outdoor Unit The heat exchanger coils and panel vents of the outdoor unit should be checked regularly If clogged with dirt or soot the heat exchanger and panel vents may be professionally steam cleaned Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs NOTE ...

Page 18: ... of the indoor outdoor unit are not blocked Do not overcool the room This is not good for the health and wastes electricity Make sure that the doors and windows are shut tight Avoid opening doors and windows as much as possible to keep the cool air in the room Keep blinds or curtains closed Do not let direct sunshine enter the room when the air conditioner is in operation Clean the air filter regu...

Page 19: ...a damp smell exuded by the walls carpet furniture or cloth items in the room Condensation occurs when the airflow from the air conditioner cools the warm room air This is the protector of the mechanism Wait about three minutes and operation will begin Is the air filter dirty See air filter cleaning instructions Has the temperature been set incorrectly Are the indoor unit s air inlet or outlet vent...

Page 20: ...20 Room Air Conditioner ...

Reviews: