background image

4

Room Air Conditioner

Safety Precautions

Two or more people must lift and
transport the product. 

• Avoid personal injury. 

Do not install the product where it will be
exposed to sea wind (salt spray) directly.

• It may cause corrosion on the product. 

Install the drain hose to ensure that the
condensed  water is drained away properly. 

• A bad connection may cause water leakage.

Keep level even when installing the
product.

• To avoid vibration or noise.

Do not install the product where the noise
or hot air from the outdoor unit could
damage or  disturb the neighborhoods.

• It may cause a problem for your neighbors

and hence dispute.

Always check for gas (refrigerant)
leakage after installation or repair of
product.

• Low refrigerant levels may cause failure of

product.

Indoor/outdoor wiring connections must  be
secured tightly and the cable should be routed
properly so that there is no force pulling the
cable from the connection terminals.

• Improper or loose connections can cause

heat  generation or fire.

Safely dispose off the packing materials. Like
screws, nails, batteries, broken things etc
after installation or svc and then tear away
and thraw away the plastic packaging bags.

• Children may play with them and cause

injury.

Make sure to check that the power cable
plug is not dirty, loose or broken  and
then only insert the plug completely.

• Dirty, loose or broken power plug can

cause electric shock or fire.

Be sure to check the refrigerant to the
used. Please read the label on the product.

• Incorrect refrigerant used can prevent the

normal operation of the unit.

Don't use a power cord, a plug  or a loose
socket which is damaged.

• Otherwise it  may cause a fire or electrical

shock.

Do not touch , operate, or repair  the
product with wet hands. Hold the plug by
hand when taking out 

• There is risk of electric shock  or fire.

Do not place a heater or other heating
appliances near the power cable.

• There is risk of fire and electric shock.

Do not allow water to run into electric parts.
Install the unit away from water sources.

• There is risk of fire, failure of the product, or

electric shock.

Do not store or use or even allow flammable
gas or combustibles near the product. 

• There is risk of fire.

Do not use the product in a tightly closed
space for a long time. Perform ventilation
regularly.

• Oxygen deficiency could occur and hence

harm your health.

Do not open the front  grille of the product
during operation. (Do not touch the
electrostatic filter, if the unit is so equipped.) 

• There is risk of physical injury, electric shock,

or product failure.

If strange sounds, smell or smoke comes
from product.Immediately turn the breaker
off or disconnect the power supply cable.

• There is risk of electric shock or fire.

Ventilate the product room  from time to
time when operating it together with a
stove, or heating element etc.

• Oxygen deficiency can occur and hence harm

your health.

Turn the main power off and unplug the
unit when cleaning or repairing the
product. 

• There is risk of electric shock.

When the product is not to  be used for a
long time, disconnect the power supply
plug or turn off the breaker.

• There is risk of product damage or failure, or

unintended operation.

Take care to ensure that nobody especially
kids could step on or fall onto the outdoor unit. 

• This could result in personal injury and

product damage. 

Take care to ensure that power cable could not
be pulled out or damaged during operation.

• There is risk of fire or electric shock.

Do not place ANYTHING  on the power
cable.

• There is risk of fire or electric shock.

Do not plug or unplug the power supply
plug to turn the unit ON/OFF .

• There is risk of fire or electric shock.

When flammable gas leaks, turn off the
gas and open a window for ventilation
before turn the product on. 

• Do not use the telephone or turn switches on

or off. There is risk of explosion or fire.

For inner cleaning, contact an Authorized
Service Center or a dealer. 
Do not use harsh detergent that causes
corrosion or damage on the unit.

• Harsh detergent may also cause failure of

product, fire, or electronic shock.

Summary of Contents for G09LH

Page 1: ...et and retain it for future reference The equipment complies with requirements of the Technical Regulation in terms of restrictions for the use of certain dangerous substances in electrical and electronic equipment P NO MFL41604505_v1 www lg com KZ O 02 0561 ENGLISH êìëëäàâ üáõä ìäêÄ çëúäÄ ...

Page 2: ...stallation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to ensure that they do not play with the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts A Safety Precautions 3 B Electrical Safety 6 Temp...

Page 3: ...ecurely There is risk of fire or electric shock due to dust water etc Use the correctly rated breaker or fuse There is risk of fire or electric shock Do not modify or extend the power cable If the power cable or cord has scrathes or skin peeled off or deteriorated then it must be replaced There is risk of fire or electric shock For installation removal or reinstall always contact the dealer or an ...

Page 4: ...ric shock Do not allow water to run into electric parts Install the unit away from water sources There is risk of fire failure of the product or electric shock Do not store or use or even allow flammable gas or combustibles near the product There is risk of fire Do not use the product in a tightly closed space for a long time Perform ventilation regularly Oxygen deficiency could occur and hence ha...

Page 5: ...y If the refrigerant gas leaks during the installation ventilate the area immediately Otherwise it can be harmfull for your health Dismantling the unit treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards Replace the all batteries in the remote control with new ones of the same type Do not mix old and new batteries or different types of...

Page 6: ...nuine adapter available from most local hardware stores Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection To disconnect the power cord from the adapter use one hand on each to avoid damaging the ground terminal Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage Never use the applia...

Page 7: ... and auto restart setting Timer Defrost mode Lights up during defrost mode or hot start operation Heat pump model only Lights up during outdoor unit operation Cooling model only Outdoor unit operation OUT DOOR Hot start operation Stops the indoor fan in heating operation for minutes to prevent cold air from blowing out from unit In defrost mode unit stops heating operation for few minutes to remov...

Page 8: ...h of the batteries 4 Use 2 AAA 1 5volt batteries NOTE 1 Choose a suitable place where its safe easy to reach 2 Fix the holder to wall etc with the supplied screws firmly 3 Slide the remote controller inside the holder 1 Remote controller should never be exposed to direct sunlight 2 Signal transmitter receiver should always be clean for proper communication Use a soft cloth to clean them 3 In case ...

Page 9: ...ment and set the desired up down airflow direction OPERATION MODE SELECTION BUTTON Used to select the operation mode OFF TIMER BUTTON Used to set the time of stopping operation START STOP BUTTON Operation starts when this button is pressed and stops when the button is pressed again ROOM TEMPERATURE SETTING BUTTONS INDOOR FAN SPEED SELECTION BUTTON JET COOL Used to start or stop the speed cooling S...

Page 10: ...Each time the button is pressed the operation mode is shifted in the arrow direction Set the temperature lower than the room temperature The temperature can be set within a range of 18 C 30 C by 1 C Set the fan speed Select the fan speed in four steps low medium high or CHAOS Each time the button is pressed the fan speed mode is shifted The display shows high fan speed Cooling Operation 1 2 3 4 Na...

Page 11: ...is pressed the fan speed mode is shifted 1 2 3 This mode dehumidifies without overcooling During Healthy Dehumidification Operation If you select the dehumidification mode on the operation selection button the airconditioner starts to run the dehumidification function automatically setting the room temp and airflow volume to the best condition for dehumidification based on the sensed current room ...

Page 12: ...1 hour to 7 hours Timer control Setting OFF TIMER CONTROL SETTING Press the Start Stop button The unit will respond with a beep To select Heating Operation press the Operation Mode Selection button Each time the button is pressed the operation mode is shifted in the direction of the arrow Set the temperature higher than the room temperature The temperature can be set within a range of 16 C 30 C in...

Page 13: ... the normal cooling mode from the JET COOL mode you just press either the operation mode selection button airflow volume selection or temp setting button or the JET COOL button again NOTE Press the Start Stop button The unit will respond with a beep Press the Jet Cool button to operate the speed cooling mode and the unit will operate in super high fan speed on cooling mode for 30 minutes To cancel...

Page 14: ...Cooling Cooling Healthy Dehumidification Heating Indoor FAN Speed High High High High Setting Temperature 22 C 22 C 23 C 24 C Test operation During the TEST OPERATION the unit operates in cooling mode at high speed fan regardless of room temperature and resets in 18 minutes During test operation if remote controller signal is received the unit operates as remote controller sets If you want to use ...

Page 15: ...rithm to distribute the air in the room evenly and at the same time to make the human body feel most comfortable as if enjoying natural breeze Always use the remote controller to adjust the up and down air flow direction Manually moving the vertical air flow direction louver by hand could damage the mechanism When the unit is shut off the up down airflow direction louver will close the air outlet ...

Page 16: ...the self explanatory diagrams for each model type Clean the filters with a vacuum cleaner or warm soapy water If dirt is not easily removed wash with a solution of detergent in luke warm water Dry well in shade after washing and reinstall the filters back in place Removal of Filters Open the front panel as shown Then pull the filter tab slightly forward to remove the air filter Gasoline Powder Pla...

Page 17: ...t of the indoor outdoor unit are not blocked Do not overcool the room This is not good for the health and wastes electricity Make sure that the doors and windows are shut tight Avoid opening doors and windows as much as possible to keep the cool air in the room Keep blinds or curtains closed Do not let direct sunshine enter the room when the air conditioner is in operation Clean the air filter reg...

Page 18: ... damp smell exuded by the walls carpet furniture or cloth items in the room Condensation occurs when the airflow from the air conditioner cools the warm room air This is the protector of the mechanism Wait about three minutes and operation will begin Is the air filter dirty See air filter cleaning instructions Has the temperature been set incorrectly Are the indoor unit s air inlet or outlet vents...

Page 19: ......

Reviews: