DESCRIPTION OF BLOCK DIAGRAM
1. Video Controller Part.
This part amplifies the level of video signal for the digital conversion and converts from the analog video signal to the
digital video signal using a pixel clock.
The pixel clock for each mode is generated by the PLL.
The range of the pixel clock is from 25MHz to 136MHz in W1943S case(28MHz to 146MHz In W1943S CASE).
This part consists of the Scaler, ADC convertor, TMDS receiver and LVDS transmitter.
The Scaler gets the video signal converted analog to digital, interpolates input to 1360 X
768 resolution signal and outputs 8-bit R, G, B signal to transmitter.
2. Power Part.
This part consists of the one 5V, and one 3.3V regulators to convert power which is provided 5V in Adapter.
18V is provided for inverter, 5V is provided for LCD panel and micom in W1943S case .
Also, 5V is converted 3.3V by regulator. Converted power is provided for IC in the main board.
The inverter converts from DC18V to AC 700Vrms and operates back-light lamps of module in W1943S case.
3. MICOM Part.
This part is include video controller part. And this part consists of EEPROM IC which stores control data, Reset IC and
the Micom.
The Micom distinguishes polarity and frequency of the H/V sync are supplied from signal cable.
The controlled data of each modes is stored in EEPROM.
Copyright
2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Summary of Contents for Flatron W1943S
Page 19: ...EXPLODED VIEW 19 300 320 410 910 920 930 430 440 200 310 330 460 400 ...
Page 20: ......
Page 21: ......
Page 22: ......
Page 23: ......