SERVICE OSD
1) Turn off the power switch at the front side of the display.
2) Wait for about 5 seconds and press MENU, POWER switch with 1 second interval.
3) The SVC OSD menu contains additional menus that the User OSD menu as described below.
a) Auto Color : W/B balance and Automatically sets the gain and offset value.
b) NVRAM INIT : EEPROM initialize.(24C08)
c) CLEAR ETI : To initialize using time.
d) AGING : Select Aging mode(on/off).
e) R/G/B-9300K : Allows you to set the R/G/B-9300K value manually.
f) R/G/B-6500K : Allows you to set the R/G/B-6500K value manually.
g) R/G/B-Offset : Allows you to set the R/G/B-Offset value manually.(Analog Only)
h) R/G/B-Gain : Allows you to set the R/G/B-Gain value manually.(Analog Only)
i) MODULE : To select applied module.
Summary of Contents for FLATRON L1910S
Page 20: ...EXPLODED VIEW 18 010 020 050 080 070 060 090 110 100 030 040 ...
Page 24: ...SCHEMATIC DIAGRAM 22 1 ZAN3SL 3 Waveforms U201 88 4 U201 94 3 4 ...
Page 25: ... 23 2 MICOM 2 U501 8 U501 ST DET 19 Waveforms 2 5 7 7 5 R213 R779 H Sync 5 R214 R775 V Sync ...
Page 26: ... 24 3 POWER ...
Page 27: ... 25 4 CONNECTOR JACKS 1 Waveforms J705 5 6 6 R213 R779 H Sync 6 R214 R775 V Sync 6 1 ...
Page 28: ...Blank Page1 ...
Page 29: ...Blank Page2 ...