7-5. TROUBLESHOOTING WITH ERROR
Water Inlet Error (IE)
Is the water tap
closed
?
[Note] Environmental safety check list
1. No water tap leakage & freeze.
2. No entanglement of water supply hose.
3. No water shortage.
4. No water supply hose leakage.
5. No the inlet filter clogged.
Check
the
Water tap
and open it
fully
.
When there is water in the tub,
is the water level frequency
over 25.5KHz
?
Reconnect or repair
the
Connector
.
Or replace
the
Harness
.
Replace
the
Inlet Valve
.
Is the
Connector
connected correctly to
the
Main PCB
and the
Inlet Valve
?
Or is the
Harness
alright ?
Check
the
Air Chamber
and
the Tube
(clogged)
And When you check the water level frequency again,
if it is over 25.5KHz, you
replace
the Pressure switch.
YES
YES
NO
NO
Replace
the
Main PCB
.
NO
YES
YES
NO
NO
Is the each resistance of Inlet Valve within
3.5 ~4.5 k
Ω
?
When the washing machine is started,
is operated the inlet valve?
Pre. Valve
Main Valve