D. REMOVING MAGNETRON
(Figures 11 Through 13)
(1) Remove the vent grille by loosening two screws.
(Figure 11)
(2) Remove the outcase. See page 7-6.
(3) Remove three tap tite screws securing the
magnetron to the wave guide.
(4) Remove the magnetron VERY CAREFULLY.
NOTES:
•
When removing the magnetron, make sure that its
dome does not hit any adjacent parts, or it may be
damaged.
•
When replacing the magnetron, be sure to install the
magnetron gasket in the correct position and be sure
that the gasket is in good condition.
•
After replacing the magnetron, check for microwave
energy leakage with a survey meter Check
microwave energy leakage must be below the limit
of 5 mW/cm
2
. (All service adjustments should be
made for minimum microwave energy leakage
readings.)
Figure 11
Figure 13
7-8
Figure 12
Vent Grille
Controller
(3 screws)
Door
Mounting
Plate
(1 or 2 screws)
Out Case
Mount,All