background image

15

ADVANCED FUNCTIONS

Disabling auto restart

Operating the air conditioner

without the remote control

unit to operate the air conditioner when the

remote control is unavailable. However, the

fan speed is set to high.

1

Open the front grille.
- Lift up both sides of the front grille slightly.

1

Open the front grille.
- Lift up both sides of the front grille slightly.

* The feature can be changed according to

type of model.

2

seconds.
- The unit will beep twice and the lamp will

blink twice 4 times.

- To re-enable the function, press the On/

unit will beep twice and the lamp will

blink 4 times.

* The feature can be changed according to

type of model.

* The feature can be changed according to

type of model.

NOTE

!

for 3 – 5 seconds instead of 6 seconds,

the unit will switch to the test operation.

In the test operation, the unit blows out

strong air for cooling for 18 minutes and

then returns to the factory default set-

tings.

Restarting the air conditioner

automatically

When the air conditioner is turned on again

after a power failure, this function restores the

previous settings. This function is a factory de-

fault setting.

2

- The temperature is set to 22

°C 

(72

°F

)

* The feature can be changed according to

type of model.

ON/OFF

button

ON/OFF

button

Summary of Contents for E10MIV SW0

Page 1: ...DITIONER Please read this manual carefully before operating your set and retain it for future reference TYPE WALL MOUNTED MODELS P NO MFL68062205 Rev 00 Date 01 2014 www lg com MFL68062205 E10MIV SW0 E13MIV SH0 LG New Hybrid ...

Page 2: ...urchase Do not cool excessively indoors This may be harmful for your health and may consume more electricity Block sunlight with blinds or curtains while you are operating the air conditioner Keep doors or windows closed tightly while you are operating the air conditioner y to circulate indoor air Speed up the fan to cool or warm indoor air quickly in a short period of time Open windows regularly ...

Page 3: ...o so may result in electric shock or product failure Contact an authorized service center when you install or relocate the air conditioner Failure to do so may result in serious injury or product failure Always use a power plug and socket with a ground terminal Failure to do so may result in electric shock or product failure Install the panel and the cover of the control box safely Failure to do s...

Page 4: ...ventilate sufficiently before using the air conditioner again Failure to do so Unplug the power plug if there is a noise smell or smoke coming from the air conditioner Failure to Stop operating and close the window in strom or hurricane If possible remove the product from the window before hurricane arrives grille Failure to do so may result in elec tric shock or product failure Contact an authorize...

Page 5: ...t failure Do not use strong cleaning agents or solvents when you clean the air conditioner or spray water Use a smooth cloth It may result in serious injury or product failure Never touch the metal parts of the air conditioner when you r rious injury or product failure Do not place any objects on the air conditioner It may result in product failure ter every two weeks or more often if necessary Do...

Page 6: ...onditioner automatically at a set time 11 T automatically at a set time 11 Canceling the timer setting 12 Setting sleep mode 12 ADVANCED FUNCTIONS 12 Changing room temperature quickly 13 13 Auto clean operation 14 Active energy control operation 15 Operating the air conditioner without the remote control 15 Restarting the air conditioner automatically 16 MAINTENANCE 17 Cleaning the Triple filter O...

Page 7: ... depending on the model of the air conditioner 7 BEFORE USE The feature can be changed according to type of model The feature can be changed according to type of model BEFORE USE Components Indoor unit Air inlet ON OFF button Signal receiver Display screen Vertical louver Air outlet Front Grille Ionizer Optional Horizontal vane Horizontal vane ...

Page 8: ...rol 1 Choose a safe and easily accessible place 2 Fix the holder by fastening the 2 screws 3 Slide the remote control into the holder Point the remote control towards the signal receiver at the bottom of the air conditioner to operate it NOTE If the display screen of the remote control starts to fade replace the batteries NOTE The remote control may operate other electronic devices if pointed towa...

Page 9: ... speed Adjusts the air Adjusts the brightness of the indoor unit display Light button On Off button Temperature adjustment button Operation mode selection button Jet cooling button Indoor fan speed button Air flow direction button Timer button Set clear button Reset button Display screen Control panel Air circulation button Used to circu late the room air without cooling Active energy control Opti...

Page 10: ...ss repeatedly to select the dehu midifying operation is displayed on the display screen NOTE In this mode you cannot adjust the room temperature as it is adjusted automati cally Also the room temperature is not displayed on the display screen BASIC FUNCTIONS 10 Airing your room Air Circulation operation This mode only circulates the indoor air without changing the room temperature The cooling lamp...

Page 11: ...ress to adjust the direction of the 2 Press or to select the times 3 Press Turning on the air conditioner auto matically at a set time 1 Press the display screen 2 Press or to select the times 3 Press 4 When setting the timer current time and ON icon are displayed on the display screen indicating that the desired time is set T to matically at a set time 1 Press the display screen 2 Press or to sel...

Page 12: ... quickly in winter 1 Press to turn on the power 2 Press NOTE Powerful Cooling Cooling Only Model Enable in Cooling Dehumidifying Fan In jet cooling mode strong air blows out at a temperature of 18 C 64 F for 30 minutes NOTE In the Cooling and Dehumidifying modes In this mode setting fan speed to low and you cannot adjust the fan speed the temperature increases by 1 C after 30 minutes and by a furt...

Page 13: ...re KEY is pressed for 5 seconds Display screen brightness You can adjust the brightness of the indoor unit display screen 1 Press Auto operation Artificial intelligence In this mode the fan speed and the temperature adjust automatically based on the room temperature 1 Press to turn on the power 2 Press repeatedly to select auto opera tion 3 Press or to select the desired oper ation code if the tem...

Page 14: ...d on the screen 6 Press one more time to return to the normal cooling operation Indoor unit display Indoor unit display Indoor unit display NOTE Due to Active energy control operation Active energy control operation is memorized You can set desired temperature in Active Ex In case of restarting the air conditioner during Active energy control operation 80 It operates Active energy control operatio...

Page 15: ...on press the On unit will beep twice and the lamp will blink 4 times The feature can be changed according to type of model The feature can be changed according to type of model NOTE for 3 5 seconds instead of 6 seconds the unit will switch to the test operation In the test operation the unit blows out strong air for cooling for 18 minutes and then returns to the factory default set tings Restartin...

Page 16: ...ge the surface of the product NOTE the model Make sure to clean the heat exchanger coils of the outdoor unit regularly as dirt collected The feature can be changed according to type of model 3M filter Optional 3M filter Optional or Triple filter Optional Item Cleaning interval Cleaning method 2 weeks 1 month Indoor unit surface Air filter 3M filter Regularly Use a soft dry cloth Do not use bleach ...

Page 17: ...t an Authorized Service center or a dealer Do not use harsh detergent that causes corrosion or damage on the unit Harsh detergent may also cause failure of The feature can be changed according to type of model Cleaning Air filter every 2 weeks or lift it up slightly 2 Open the front cover and remove 1 cord 3 4 Use a vacuum cleaner to remove any dirt NOTE depending on the model Cleaning the 3M filt...

Page 18: ...ntact the service center Water leaks from the indoor unit even when the humidity level is low The power cord is damaged or generating excessive heat A switch a circuit breaker safety ground or a fuse is not operated properly The air conditioner does not work The air conditioner is unplugged Check whether the power cord is plugged into the outlet A fuse is blown or the power supply is blocked Repla...

Page 19: ...r a gas burner while the air conditioner is in operation Air circulation opera tion is selected In the air circulation operation air blows from the air conditioner without cooling or heating the indoor air Switch the opera tion mode to the cooling operation It is not possible to adjust the fan speed The auto operation jet operation or dehu midifying operation is selected In some operation modes su...

Page 20: ...PT LG ELECTRONICS INDONESIA Kawasan Industri MM2100 Blok G Cikarang Barat Bekasi Jawa Barat 17520 INDONESIA ...

Page 21: ...E10MIV SW0 E13MIV SH0 LG New Hybrid ...

Page 22: ... berlebihan Hal ini akan membahayakan kesehatan Anda dan dapat mengonsumsi listrik lebih banyak Halangilah sinar matahari dengan kerai atau gorden ketika Anda sedang mengoperasikan penyejuk udara Tetap tutup pintu atau jendela rapat rapat ketika Anda tengah mengoperasikan penyejuk udara Sesuaikan arah aliran udara secara vertikal atau horizontal untuk menyirkulasikan udara dalam ruangan Percepatla...

Page 23: ...an listrik atau kegagalan produk Hubungilah pusat servis resmi bila Anda memasang atau memindahkan penyejuk udara Kelalaian melakukan hal ini dapat menimbulkan cedera serius atau kegagalan produk Gunakan selalu steker daya dan soket dengan terminal arde Kelalaian melakukan hal ini dapat menimbulkan kejutan listrik atau kegagalan produk Pasanglah panel dan penutup kotak kendali dengan aman Kelalaia...

Page 24: ...an gas beri ventilasi yang memadai sebelum menggunakan penyejuk udara kembali Kelalaian melakukan hal ini dapat menimbulkan ledakan atau kebakaran Lepaslah colokan steker daya jika ada suara berisik bau atau asap yang keluar dari penyejuk udara Kelalaian melakukan hal ini dapat menimbulkan ledakan atau kebakaran Hentikan pengoperasian dan tutuplah jendela saat ada badai atau topan Jika memungkinka...

Page 25: ...g kuat ketika Anda membersihkan penyejuk udara atau air semprotan Gunakanlah kain yang halus Hal ini dapat menimbulkan cedera serius atau kegagalan produk ini dapat menimbulkan cedera serius atau kegagalan produk Jangan letakkan benda apa pun di atas penyejuk udara Hal ini dapat menimbulkan kegagalan produk minggu atau lebih sering lagi jika perlu Jangan masukkan tangan atau benda lain ke dalam ma...

Page 26: ...EMECAHAN MASALAH 11 Mengatur waktu saat ini 18 Fungsi diagnosis mandiri 11 Menyalakan penyejuk udara secara otomatis pada waktu tertentu 18 Sebelum menelepon petugas servis 11 Mematikan penyejuk udara secara otomatis pada waktu tertentu 11 Membatalkan pengaturan timer 12 Mengatur mode tidur DAFTAR ISI Operasi Auto Clean Pembersihan Otomatis 13 Pemurnian udara dalam ruangan 13 Mode Perawatan Kulit ...

Page 27: ...Dasar Kabel penghubung Pemipaan Selang Penguras SEBELUM MENGGUNAKAN Komponen Unit dalam ruangan Fitur ini bisa berubah menurut tipe model SEBELUM MENGGUNAKAN 7 Masukan udara Tombol ON OFF Penerima Sinyal Baling baling Ionizer Opsional horizontal Bingkai bukaan louver vertikal Keluaran udara Gril depan Display screen Filter 3M Opsional Filter udara Filter 3M Opsional atau Filter triple Opsional ...

Page 28: ...sinyal penyejuk udara Agar pengoperasiannya tetap baik gunakan kain lembut untuk membersihkan penerima dan pemancar sinyal 3 Pasang kembali penutup baterai Cara mengoperasikan Memasukkan baterai Masukkan baterai sebelum menggunakan remote control Tipe baterai yang digunakan adalah AAA 1 5 V 1 Lepaskan penutup baterai 2 Masukkan baterai baru dan pastikan terminal dan baterai dipasang dengan benar 3...

Page 29: ...u Menampilkan suhu ruangan dan juga perubahan unit dari C ke F jika terdesak untuk 5 detik Tombol otomatis mode tidur Mengatur pengoperasian otomatis mode tidur Tombol timer Mengatur waktu saat ini dan waktu mulai selesai Tombol Set clear Seting waktu atau membatalkan fungsi Tombol reset Memulai pengaturan penyejuk udara Menyesuaikan kecerahan layar tampilan unit dalam ruangan Tombol Light o o hr ...

Page 30: ...ini menyesuaikan suhu ruangan dan kipas angin secara otomatis untuk mempertahankan level kelembapan yang optimal 1 Tekan untuk menyalakan daya 2 Tekan berulang ulang untuk me milih operasi penghilangan lembap ditampilkan di layar tampilan FUNGSI DASAR CATATAN Menganginkan ruangan Anda Operasi Sirkulasi Udara Mode ini hanya menyirkulasikan udara dalam ruangan tanpa mengubah suhu ruangan Lampu pendi...

Page 31: ...ilkan di layar tampilan yang menunjukkan bahwa waktu yang diinginkan telah disetel Mematikan penyejuk udara secara otomatis pada waktu tertentu 1 Tekan Ikon di bawah ini berkedip di bawah layar tampilan 2 Tekan atau untuk memilih waktu 3 Tekan untuk menyelesaikan 4 Ketika mengatur timer waktu saat ini dan ikon OFF ditampilkan di layar tampilan yang menunjukkan bahwa waktu yang diinginkan telah dis...

Page 32: ...lih jam hingga 7 jam 4 Tekan untuk menyelesaikan ditampilkan di layar tampilan dal am mode tidur CATATAN FUNGSITINGKAT LANJUT Penyejuk udara ini menawarkan beberapa fungsi tambahan tingkat lanjut Mengubah suhu ruangan dengan cepat Jet Cool Mode ini memungkinkan Anda mendinginkan udara dalam ruangan dengan cepat di musim panas atau menghangatkannya dengan cepat di musim dingin 1 Tekan untuk menyala...

Page 33: ...au F ke C jika TOMBOL Suhu Ruangan ditekan selama 5 detik Kecerahan layar tampilan Anda dapat menyesuaikan kecerahan layar tampilan unit dalam ruangan 1 Tekan untuk menyalakan mematikan layar Tampilan Pengoperasian otomatis Kecerdasan buatan Dalam mode ini kecepatan kipas dan suhu disesuaikan secara otomatis berdasarkan suhu ruangan untuk menyalakan daya 2 Tekan 1 Tekan berulang ulang untuk memili...

Page 34: ...normal yang tertera Saat Active energy control di pilih anda dapat mengatur temperatur yang diinginkan di dalam pengoperasian Active energy control Pengaturan temperature akan ditampilkan selama 5 detik lalu kemudian kembali ke tampilan 80 60 40 Pengaturan Active energy control dapat di simpan Contoh Saat pengoperasian Active energy control 80 matikan lalu nyalakan kembali mesin penyejuk udara mak...

Page 35: ...kan kembali fungsi ini detik Unit ini akan mengeluarkan bunyi bip dua kali dan lampu akan berkedip 4 kali Mengoperasikan penyejuk udara tanpa remote control unit dalam ruangan untuk mengoperasikan penyejuk udara bila remote control tidak tersedia Namun kecepatan kipas diatur ke tinggi 1 Buka gril depan Angkat sedikit kedua sisi penutup Fitur ini bisa berubah menurut tipe model 2 Tekan tombol ON OF...

Page 36: ...aan produk Pastikan untuk membersihkan kabel pert ukaran panas unit luar ruangan secara teratur meningkatkan biaya energi CATATAN PERHATIAN Fitur ini bisa berubah menurut tipe model Filter 3M Opsional Filter udara Filter 3M Opsional atau Filter triple Opsional Cleaning method 2 minggu 1 bulan Permukaan unit dalam ruangan Secara teratur Gunakan kain lembut dan kering Jangan gunakan zat pengikis ata...

Page 37: ...jen yg keras sebab akan menimbulkan karat dan kerusakan didalam unitDiterjen yang keras dapat juga menyebabkan kerusakan pada produk kebakaran atau korsleting listrik CATATAN Membersihkan filter triple Opsional 1 Matikan daya dan cabut steker kabel daya 2 4 terkena sinar matahari selama 2 jam tergantung model CATATAN Fitur ini bisa berubah menurut tipe model 3 4 Gunakan vacuum cleaner untuk menghi...

Page 38: ...Ada kebocoran air dari unit dalam ruangan meskipun level kelembapan rendah Kabel daya rusak atau menghasikan panas berlebihan Ada sakelar pemutus sirkuit pengaman arde atau sekring yang tidak berfungsi baik Penyejuk udara tidak hidup Steker penyejuk udara belum dipasang Periksa apakah kabel daya sudah dipasang ke stopkontaknya Sekring putus atau suplai daya terblokir Gantilah sekring dan periksa a...

Page 39: ... penggunaan generator panas seperti kompor gas atau oven listrik saat penyejuk udara dioperasikan Operasi sirkulasi udara telah dipilih Dalam operasi sirkulasi udara udara berhembus dari penyejuk udara tanpa mendinginkan atau memanaskan udara dalam ruangan Alihkan mode pengoperasian ke operasi pendinginan Anda tidak bisa mengatur kecepatan kipas angin Operasi otomatis operasi singkat jet atau oper...

Page 40: ...PT LG ELECTRONICS INDONESIA Kawasan Industri MM2100 Blok G Cikarang Barat Bekasi Jawa Barat 17520 INDONESIA ...