background image

En-7

WEEKLY TIMER

● 

To start

CLOCK ADJUST

When the weekly timer is selected, the
timer starts automatically.

The operating time for the current
day is displayed.

● 

To cancel

Press the DELETE button to cancel
the timer mode.

The timer mode can also be
canceled by changing the timer
mode using the timer mode button.

To set the DAY OFF (for a holiday)

1

During the weekly timer,
press the SET button for 2
seconds or more to set the
day.

SET

Select the day to set the DAY
OFF.

Press the DAY (DAY OFF)
button for 2 seconds or
more to set the DAY OFF.

Press the SET button for 2
seconds or more to com-
plete the DAY OFF setting.

2

4

DAY OFF

DAY

SET

3

DAY OFF

DAY

SU MO TU WE TH FR SA

3 6 9 12 15 18 21

SU MO TU WE TH FR SA

3 6 9 12 15 18 21

To cancel

Follow the same procedures as

those for setup.

ex. The DAY OFF is set for Monday.

NOTES

The DAY OFF setting is only available for days for which weekly settings already exist.

If the operating time carries over to the next day (during a next day setting), the effective DAY OFF range will be set as
shown below.

● 

Normal

● 

Next day setting

Setting day

Preceding day

 Next day

Setting day

Preceding day

 Next day

The DAY OFF setting can only be set one time. The DAY OFF setting is cancelled automatically after the set day has
passed.

 mark: Indicates the DAY OFF

ON

OFF

ON

OFF

DAY OFF

WEEKLY

WEEKLY

WEEKLY

WEEKLY

ON

OFF

ON

OFF

DAY OFF

DELETE

WEEKLY timer operation

SU MO TU WE TH FR SA

3 6 9 12 15 18 21

3 6 9 12 15 18 21

ex. Operating time 7:00-18:00

9373117049̲P1-14̲EN

05.2.18, 12:31

7

Summary of Contents for Duct series

Page 1: ...EDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES English Deutsch Français Español Italiano EλληvIkά Português AIR CONDITIONER DUCT TYPE SU MO TU WE TH FR SA AM PM 3 6 9 12 15 18 21 9373117049 cover 05 2 16 09 14 1 ...

Page 2: ...tly to water Do not operate the air conditioner with wet hands Turn off power source when not using the unit for extended periods Always turn off the electrical breaker whenever cleaning the air conditioner or changing the air filter Connection valves become hot during Heating handle with care Check the condition of the installation stand for damage Do not place animals or plants in the direct pat...

Page 3: ...n SetTime Button DELETE Button SET Button Operation Lamp Timer and Clock Display Operation Mode Display Fan Speed Display Operation Lock Display Temperature Display Function Display Defrost Display Thermo Sensor Display Energy Save Display DAY OFF DELETE SET ENERGY SAVE THERMO SENSOR SET BACK DAY CLOCK ADJUST SU MO TU WE TH FR SA 3 6 9 12 15 18 21 D 2 7 8 9 0 A B G F E H I C 1 3 4 5 6 9373117049 P...

Page 4: ...time Press repeatedly to adjust the current time in 1 minute increments Press and hold to adjust the current time in 10 minute increments ex Monday 10 00 Press again to end CLOCK ADJUST SU MO TU WE TH FR SA 1 3 4 AUTO COOL DRY HEAT FAN AUTO HIGH MED LOW Temperature setting range AUTO 18 to 30 C COOL DRY 18 to 30 C HEAT 16 to 30 C Lower Rise Operation lamp Air conditioner ON Lit brightly Air condit...

Page 5: ... the mark appears If any button is pressed during the child lock the CL display flashes Room temperature sensor selection Press the THERMO SENSOR button to select whether the room temperature is detected at the indoor unit remote sensor or the remote controller When the thermo sensor display appears the room temperature is detected at the remote controller NOTES This function is locked at the fact...

Page 6: ...sed to repeat the timer settings for all of the days Temperature SET BACK timer See page 8 Use this timer function to change the set temperature in the operation times set for each day of the week This can be used together with other timer settings ON OFF TIMER Press the timer mode button to se lect the ON timer or OFF timer 2 Press the DELETE button to cancel the timer mode The timer mode can als...

Page 7: ...d OFF times can be set per day Press the DAY button to complete the time setting and return to the day of the week setting When the operating time is set the mark appears 5 Repeat steps 3 and 4 To complete the weekly timer settings press the SET button for 2 seconds or more SET To delete the operating time DELETE If the DELETE button is pressed during steps 3 or 4 the operating time for the select...

Page 8: ...U WE TH FR SA 3 6 9 12 15 18 21 SU MO TU WE TH FR SA 3 6 9 12 15 18 21 To cancel Follow the same procedures as those for setup ex The DAY OFF is set for Monday NOTES The DAY OFF setting is only available for days for which weekly settings already exist If the operating time carries over to the next day during a next day setting the effective DAY OFF range will be set as shown below Normal Next day...

Page 9: ...T 4 SU MO TU WE TH FR SA 3 6 9 12 15 18 21 ex When setting all days together Temperature setting Press the set temperature buttons to set the temperature The temperature setting range is the same as the range for the operation mode ex Operating time 15 00 22 00 5 Repeat steps 3 and 4 Press the SET button for 2 sec onds or more to complete the temperature SET BACK timer settings SET ON OFF 24 C 24 ...

Page 10: ...ir conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insuffi cient heating performance is being produced we recom mend you use this air conditioner in conjunction with an other kind of heating appliance Heat pump air conditioners heat y...

Page 11: ... provided by your units and use the units in the way that best matches your family s lifestyle lf you discover that one or more units delivers a low level of cooling or heating during simultaneous opera tion we recommend that you stop simultaneous opera tion of the multiple units Operation cannot be done in the following different op erating modes If the indoor unit is instructed to do an operatin...

Page 12: ...er to remove dust and dirt from the air filter or wash in a synthetic detergent After washing dry in a shaded place then reinstall When used for extended periods the unit may accumulate dirt inside reducing its performance We recommend that the unit be inspected regularly in addition to your own cleaning and care For more information consult authorized service personnel When cleaning the unit s bo...

Page 13: ... operate or it will operate at a very low speed to allow the internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the indoor and the outdoor unit will stop If you wish to warm the room further set the thermostat to a higher setting During Heating operation the unit will temporarily stop opera tion between 2 and 16 minutes as theAutomatic Def...

Page 14: ...perature settings thermostat cor rectly Is there a window or door open In the case of Cooling operation is a window allowing bright sun light to enter Close the curtains In the case of Cooling operation are there heating apparatus and computers inside the room or are there too many people in the room If the problem persists after performing these checks or if you notice burning smells stop operati...

Reviews: