11
CHANGE GAS SETTING (NATURAL GAS, PROPANE GAS)
Natural Gas mode is set. Propane Gas Orifice is on sale as a Service
Part to authorized servicers only.
STEP 1 : V AL VE SETTING
STEP 2 : ORIFICE CHANGE
Natural Gas
Propane Gas
4948EL4001B
4948EL4002C
Kit contents: Orifice (Dia. = 1.47 mm, for Propane Gas)
Replacement Label
Instruction Sheet
NCU
PCK
Remove 2 screws.
Disassemble the pipe assembly.
Replace natural gas orifice with propane gas orifice.
Opened
Closed
Full open
Adjustment screw
Close
Adjustment screw
Orifice
Initially,
Changing orifices and gas valve adjustments improperly can result in an
explosion and/or fire. Conversion must be made by a qualified technician.
!
Warning
The burner is set for natural gas at the factory. The propane orifice
conversion kit is sold as a service part to autherized servicers only.
Part numbers are shown below.
FOR LG TECHNICIAN
46