30
Test 8
Semi Conductor
Caution
Trouble Symptom
Measurement Condition
Before measuring resistance, be sure to turn Power off, and do voltage discharge.
(When discharging, contact the metal plug of Power cord with earth line.)
Degree of Resistance is not in 300°æ30 Ω
Turn the Dryer’s Power Off, then measure resistance.
Normal Condition
When measuring resistance
Is resistance 300 20 Ω?
YES
NO
When measuring resistance in Semi-Conductor
Is resistance 300 20 Ω?
1. Is the measurement within the range of
300 20 Ω between Red-White?
2. Is the measurement within the range of
300 20 Ω between Black-White?
YES
NO
• Replace Control
and Check.
• Check Semi-
conductor and
Harness Connector
• Check Harness
linking connector
Take 6pin Connector from
the Controller.
B
W
R