![LG DLE3600 Series Service Manual Download Page 45](http://html.mh-extra.com/html/lg/dle3600-series/dle3600-series_service-manual_210724045.webp)
44
45
43
NOTE: This test has two parts. The best test of the door switch system is done in the diagnostic mode. This
FUNCTIONAL TEST will test the door switch, wiring harness and PCB operation. If the results of this test are
normal, the door switch system and PCB response are normal. The problem is somewhere else.
FUNCTIONAL TEST (Control)
1. Enter the diagnostic mode. (See DIAGNOSTIC TEST MODE.)
2. With the door closed, press the START/PAUSE button once. The dryer will start tumbling without heat.
3. Open the door. The drum will stop tumbling. The “dE” error code should be displayed, the chime should sound seven times (if turned on), and
the drum light (if equipped) should come on. If the “dE” error code is not displayed or the light does not come on, proceed with the
MECHANICAL TEST below. If the error displays and light comes on, the door switch is working properly.
Test 5
kGzG{
isY
X
Z
Y
~o[
X
Z
Y
NO
NO
NO
YES
YES
YES
WH4
Disconnect the WH1 and BL3 connector
from the main PCB.
Measure the resistance between the
NA6- (GN) pin and a chassis
ground screw.
Is the resistance <1 ?
Disconnect the BL2 and WH4 connector
from the main PCB.
Measure the resistance between
BL2- (WH) and WH4- (YL).
Is the resistance <1 with the
door closed and with the door
open?
*Skip this step if the dryer does not have
a drum light.
Disconnect the WH4 and the black tab
relay connectors from the main PCB.
Measure the resistance between
WH4- (YL) and WH4- (BK).
Is the resistance <1 with the door
opened and
with the door closed?
Refer to the individual door switch and light
bulb/socket component tests.
•
Replace the main
PCB.
•
Check all wiring
harness
connections wire
and ground
screws.
•
Replace the light
bulb.
•
Replace the light
socket.
[
[
42
44
45
Test 6
oGzG{GTGlG{
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YL3
BK
YL3
WH
j
{
z G
t
jG
Before measuring resistance, be sure to turn the power off, and do voltage discharge.
(When discharging, contact the metal plug of the power cord with a ground line.)
While operating, Heating will not work. Drying time takes longer.
After turning the power off, measure the resistance.
Enter diagnostic mode and press the
START/PAUSE button twice. Measure the
voltage between YL3- (WH) and the YL wire
on the black tab relay. Is the voltage 240 VAC?
Disconnect the YL3, black tab relay and white tab relay
connectors at the main PCB.
Measure the resistance between YL3- (WH) and the
BL wire on the black tab relay connector.
Is the resistance 18-22 ?
Measure the resistance between YL3-
(WH) and the YL wire on the white tab relay
connector. Is the resistance 18-22
?
?
Measure the resistance between the BL wire on the
black tab relay and the YL wire on the white tab
relay connectors. Is the resistance 36-44
Measure the resistance between terminals 1
(RD) and the heater housing.
Is the resistance <1 ?
Refer to the hi-limit thermostat and
thermal cut off component tests.
•
Check power supply.
•
Check wiring and
connectors to
the element.
•
See element
component test.
•
Check wiring and
connectors
to the element.
•
See element
component test.
•
Check wiring
and connectors to the
element.
•
See element
component test.
•
Replace the
element.
TH3
L2(Red) L2S(White)
TH2
L2S(White)
L2
(Red)
TH3
TH2
L2D(White)
Only for FLOW SENSE model
Others
Wires
L2(Red)
L2D(White) : Go to the duct(YL3 in main pcb)
L2S(White) : Go to the safety.
BK
WH
43
Summary of Contents for DLE3600 Series
Page 13: ...13 13 13 3 3 Connect Inlet Hose 21 8 150 800 800 ...
Page 18: ...18 18 15 ...
Page 21: ...21 21 21 7 WIRING DIAGRAM 18 ELECTRIC DRYER GAS DRYER ...
Page 22: ...22 22 Main PCB Picture Electric Gas 19 ...
Page 24: ...24 24 21 ...
Page 27: ...27 27 27 Electric Dryer Table 1 Resistance for Thermistor Temperature 25 ...
Page 37: ...37 36 10 DIAGNOSTIC TEST 35 T ...
Page 61: ...61 60 13 EXPLODED VIEW 13 1 Control Panel and Plate Assembly A120 A140 A110 58 A210 A211 A213 ...
Page 66: ...66 65 MAY 2020 PRINTED IN KOREA P No MFL69290439 ...