12
13. Outlet Thermostat
(Auto reset)
14. Outlet Thermostatt
(Manual reset)
Measure resistance of terminal
to terminal
Open at 203 7°F (95 5°C
Close at 159 9°F (70 5°C)
• Gas type
• Gas funnel
• Gas type
• Gas funnel
Measure resistance of terminal
to terminal
Open at 212 12°F
(110 7°C)
Manual reset
If thermal fuse is open must
be replaced
Resistance value
Continuity
<
1
Ω
•
Check Top Marking:
N95
•
Check Top Marking:
N110
Resistance value
Continuity
<
1
Ω
Component Test Procedure Check result