SPECIFICATIONS

Name

: Electric and Gas  Dryer

Power supply 

Please refer to the rating label regarding detailed

information.

Size             

: 68.6X98.3X76.1(cm)

Dryer capacity

: IEC 7.3cu.ft.

Weight

: 126(Ibs)

Specifications are subject to change by manufacturer.

■  

ACCESSORIES

Dryer rack (1 each)

See page 26  for how to use.

See  page 13 for how to use.

See page 14  for how to use.

Stacking kit (1 each)

Purchased Separately

Pedestal (1 each)

Purchased Separately

Summary of Contents for D5988W

Page 1: ...P No 3828EL3003A DLE5977W DLG5988W DLE5977B DLG5988B DLE3777W DLG3788W ...

Page 2: ...OOTING GUIDE 29 31 LG DRYER LIMITED WARRANTY 32 OUTSTANDING PERFORMANCE Not to mention unmatched big capacity you can benefit from good time efficiency quiet operation and energy saving system STAINLESS STEEL DRUM Stainless steel drum doesn t have any rust by nature so that rust free drum keeps clothes away from stain all time ARTISTIC DESIGN Modern front panel look and big crystal clear glass doo...

Page 3: ...information Size 68 6X98 3X76 1 cm Dryer capacity IEC 7 3cu ft Weight 126 Ibs Specifications are subject to change by manufacturer ACCESSORIES Dryer rack 1 each See page 26 for how to use See page 13 for how to use See page 14 for how to use Stacking kit 1 each Purchased Separately Pedestal 1 each Purchased Separately ...

Page 4: ...g to the instructions in this manual LG will repair or replace any of its mechanical or electrical parts if they are defective in material or workmanship Warranty Restriction If the dryer is subjected to other than private family use all warranty coverage is effective for only 90 days You will need the complete model and serial numbers when requesting information We recommend that you staple your ...

Page 5: ...s may contribute to a chemical reaction that could cause a load to catch fire 14 Do not use fabric softners or products to eliminate static unless recommended by the manufacturer of the fabric softner or product GROUNDING INSTRUCTIONS This appliance must be grounded In the event of malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for...

Page 6: ...il on them including cooking oil Articles containing foam rubber rubber like materials plastic or similar materials should be dried on a clothesline or by using an air cycle Failure to follow these instructions can result in fire death or serious injury A qualified service person or company must perform installation and service of this appliance California safe drinking water and toxic enforcement...

Page 7: ... manufactured or mobile home please refer to STEP 9 below for additional instructions Certain minimum clearance are required above behind and to the sides of the dryer in the ever you install it any closer of other recessed area Those required minimum clearances are set forth in the picture below Please also keep the following instructions in mind when installing in a closet or recessed area Consi...

Page 8: ...inch If the dryer is not level and if the slope exceeds 2 5 cm 1 inch a load may not tumble properly and internal sensors may malfunction Note Other sections of this manual also provide important information concerning the placement of and clearances for your dryer Please review this entire manual before proceeding with any installation The door on your dryer can be installed to open either to the...

Page 9: ...possible Use duct tape on all duct joints Insulate ductwork that runs through unheated areas in order to reduce condensation and lint build up on pipe walls and PLEASE BE AWARE THAT FAILURE TO EXHAUST THE DRYER CORRECTLY WILL VOID THE DRYER S WARRANTY WARNING Use a heavy metal vent Do not use a plastic vent Do not use a metal foil vent Failure to follow these instructions can result in death or fi...

Page 10: ...ngs and instructions concerning making the electrical connection for electric dryers More detailed information concerning the electrical connection is provided at the manual section entitled Electrical Requirements For Electric Dryer and it is important that you thoroughly review that section and the remainder of this manual before taking any steps to install or use this dryer 1 Use only a new U L...

Page 11: ...mpartment and after completing all steps in this manual for proper installation of this dryer start the dryer on a heat setting as described more fully in the operating instructions that accompany the dryer After the dryer starts the igniter will glow red and the main burner will ignite Warning If all air is not purged from the gas line the gas igniter may go off before the gas and the main burner...

Page 12: ...ented to the outside using the back left or bottom panel Gas dryer may not be vented to the outside using the right side panel because of the burner housing 6 The dryer exhaust duct must be affixed securely to the manufactured or mobile home structure and the exhaust duct must be made of a material that will resist fire and combustion and it is recommended that you use a rigid or flexible metal pi...

Page 13: ...by fitting legs as shown in the picture Avoid finger injuries be careful not to pinch fingers between the washer and dryer Slide washer slowly backwards to the stopper of kit Insert the front stacking kit Push the front stacking kit back to the stoppers of side stacking kit Screw both sides of the front kit Do not use stacking kit with a gas dryer in potentially unstable conditions like a mobile h...

Page 14: ...Part 4 1 4 ACESSORIES INSTALLATION Pedestal Installation Instructions 3 1 4 5 6 7 2 ...

Page 15: ... ELECTRICAL SERVICE FOR THE DRYER SHOULD BE OF MAXIMUM RATE VOLTAGE LISTED ON THE NAMEPLATE DO NOT CONNECT DRYER TO 110 115 OR 120 VOLT CIRCUIT Heating elements are available for field installation in dryers which are to be connected to electrical service of different voltage than that listed on nameplate d If branch circuit to dryer is fifteen feet 4 50 m or less in length use U L Underwriters La...

Page 16: ...ires a hook shape Then put the hooked shape end of the wire under the screw of the terminal block hooked end facing rightward and pinch the hook together and screw tightly Use the instructions at this section if your home has a 4 wire receptacle NEMA type 14 30R and you will be using a UL listed 120 240 volt minimum 30 amp dryer power supply cord If this type is available at your home you will be ...

Page 17: ...hen put the hooked shape end of the wire under the screw of the terminal block hooked end facing rightward and pinch the hook together and screw tightly 3 wire connection Direct wire 1 Connect neutral wire white of power cord to center terminal block screw 2 Connect red and black wire to the left and right terminal block screws 3 Connect ground wire green of power cord to external ground screw and...

Page 18: ...ernal ground connector to proper ground Part 5 ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYERS lf your local codes or ordinances permit the connection of a frame grounding conductor to the neutral wire use these instructions If your local codes or ordinances do not allow the connection of a frame grounding conductor to the neutral wire use the instructions under Section 3 Optional 3 wire connection Op...

Page 19: ... a three prong plug to help guard against shock The plug should be plugged directed into a properly grounded three prong receptacle that is rated 120 Volts AC alternating current 15 Amps This plug in order to be properly and fully effective must be plugged into a properly installed outlet that is grounded in accordance with all local codes and ordinances b The dryer must be grounded in order to re...

Page 20: ...d as shown 6 If using a rigid pipe the rigid pipe should be 1 2 inch IPS If acceptable under local codes and ordinances and when acceptable to your gas supplier 3 8 inch approved tubing may be used where lengths are less than 20 feet 6 1m Larger tubing should be used for lengths in excess of 20 feet 6 1m It is also important that you use pipe joint compound that is insoluble in LP gas 7 To reduce ...

Page 21: ...installing your new dryer 3 Rigid metal duct is recommended Do not install flexible duct in concealed spaces Non combustible flexible metal duct is acceptable Do not use plastic or thin foil ducting 4 DO NOT use sheet metal screws on exhaust pipe joints or other fastening means which extend into the duct that could catch lint and reduce the efficiency of the exhaust system Secure all joints with d...

Page 22: ...yer because wiring errors can cause serious injury to you and your dryer Cleaning the Lint Screen 1 Clean the lint filter either before drying each load or after drying each load Always make sure the lint filter is clean before starting a new load because a clogged lint filter may increase drying times 2 To clean pull the lint screen straight up and roll any lint off the screen with your fingers D...

Page 23: ...rtant Warning To reduce the risk of fire electric shock or injury to person read this entire manual including the Important Safety Instructions before operating this dryer WARNING Fire Hazard No washer can completely remove oil Do not dry anything that has ever had any type of oil on it including cooking oils Items containing foam rubber or plastic must be dried on a clothesline or by using an Air...

Page 24: ...wels 10 bath towels 10 hand towels 14 wash cloths Mixed Load 3 sheets 1 king 2 twin 4 pillowcases 3 shirts 3 blouses 9 T shirts 9 shorts 10 handkerchiefs Following are sample loads for Super Capacity Dryers To stop your dryer at any time Press START PAUSE or open the door P P P Pa a a au u u us s s si i i in n n ng g g g o o o or r r r R R R Re e e es s s st t t ta a a ar r r rt t t ti i i in n n ...

Page 25: ...ecific amount of drying time and a drying temperature When a Manual Cycle is selected the ESTIMATED TIME REMAINING display shows the actual time remaining in your cycle You can change the actual time in the cycle by pressing MORE TIME or LESS TIME Speed Dry Use for small loads or loads that need a short drying time Freshen Up Use this cycle to remove wrinkles from items such as clothes packed in a...

Page 26: ... KL L L LE E E E C C C CA A A AR R R RE E E E This chart shows examples of items that can be dried using AIR DRY Reset cycle to complete drying if needed Check to see that coverings are securely stitched Shake and fluff pillows by hand periodically during the cycle Dry item completely Foam rubber pillows are slow to dry NOTE Air Dry is not available with Sensor Dry Cycles W W W Wh h h he e e en n ...

Page 27: ... filling Stuffed toys foam rubber filled Foam rubber pillows Athletic shoes Reset time as needed to complete drying When drying washable wool items block and shape the items to lay flat on the dryer rack Select RACK DRY and MORE TIME or LESS TIME Reset time as needed to complete drying Refer to the following table Select the desired temperature setting to match the fabrics in your load by pressing...

Page 28: ...AM button then press START PAUSE 1 Open the door and pull the filter straight up 1 Wipe out the door opening Otherwise build ups of dirty and foreign objects will damage sealing of door 2 Clean the transparent glass door to keep inside view clear through the glass Run the fingers across the filter 2 Clean the filter using one of following ways in cases Vacuum the lint filter Wash the lint screen i...

Page 29: ...ripped the dryer might tumble but not heat Check your home s or laundry room s fuse box circuit breaker box and replace the fuse or reset the circuit breaker IMPORTANT electric dryers generally use two fuses or breakers Confirm that the house gas shutoff and the dryer gas shutoff are both fully open 3 Problem There are Greasy Spots on My Clothes Question What to Do Did you follow the instructions ...

Page 30: ...s shirts and other articles of clothing are empty before washing and drying Is your lint filter full Did you properly sort your load of laundry Do your clothes have excess static electricity Did you overload your dryer Did you place any paper tissue or other similar material in the load Did you use fabric softener Did you over dry the load of laundry Are you drying synthetic permanent press and bl...

Page 31: ... free of obstructions Confirm that the outside wall dampers are moving freely that the dampers are not pushed in and that nothing has been set against the dampers Check your home s or laundry room s fuse box circuit breaker box and replace the fuse or reset the circuit breaker IMPORTANT electric dryers generally use two fuses or breakers Divide your larger load into a number of smaller loads If yo...

Page 32: ...3 2 LG DRYER LIMITED WARRANTY USA 6 6 ...