background image

18 Air Conditioner

Maintenance and Service

Outdoor Unit

The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. 
If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned.

Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs.

NOTE

Operation Tips!

Do not overcool the room.

This is not good for the health and
wastes electricity.

Keep blinds or curtains
closed.

Do not let direct sunshine enter
the room when the air conditioner
is in operation.

Keep the room temperature
uniform.

Adjust the vertical and horizontal
airflow direction to ensure a
uniform temperature in the room.

Make sure that the
doors and windows
are shut tight.

Avoid opening doors and
windows as much as
possible to keep the cool
air in the room.

Clean the air filter
regularly.

Blockages in the air filter
reduce the airflow and
lower cooling and
dehumidifying effects.
Clean at least once every
two weeks.

Ventilate the room
occasionally.

Since windows are kept
closed, it is a good idea
to open them and
ventilate the room now
and then.

Use high fan speed
for effective and fast
cooling.

The unit gives its rated
cooling capacity when the
fan speed is  high.

Summary of Contents for CS05AF

Page 1: ... read this owner s manual carefully and thoroughly before installing and operating your room air conditioner Please retain this owner s manual for future reference after reading it thoroughly Type Wall Mounted ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH πÃÕ PORTUGUÊS NEDERLANDS POLSKI MAGYAR ...

Page 2: ...ould be supervised to ensure that they do not play with the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts A Safety Precautions 3 B Electrical Safety 6 Temporary Use of an Adapter 6 Temporary Use of an Extension Cord 6 Symbols used in this Manual 6 C Product Introduction 7 Indoor Units 7 Op...

Page 3: ...ly There is a risk of fire or electrical shock due to dust water etc Use the correctly rated breaker or fuse There is a risk of fire or electrical shock Do not modify or extend the power cable If the power cable or cord has scrathes or skin peeled off or deteriorated then it must be replaced There is a risk of fire or electrical shock For installation removal or reinstall always contact the dealer...

Page 4: ...ilure If strange sounds smell or smoke comes from product Immediately turn the breaker off or disconnect the power supply cable There is a risk of electrical shock or fire Ventilate the product room from time to time when operating it together with a stove or heating element etc Oxygen deficiency can occur and hence harm your health Turn the main power off and unplug the unit when cleaning or repa...

Page 5: ...igerant used in the system If air enters the refrigerant system an excessively high pressure results causing equipment damage or injury If the refrigerant gas leaks during the installation ventilate the area immediately Otherwise it can be harmfull for your health Dismantling the unit treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards...

Page 6: ...ine adapter available from most local hardware stores Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection To disconnect the power cord from the adapter use one hand on each to avoid damaging the ground terminal Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage Never use the applianc...

Page 7: ...eover heating Error code 10 digits Error Indicator lights up Blue lamp and red lamp alternately Number of lamp s blink indicate Error code Product Introduction Product Introduction Standard Split Type Display panel LED indicators Air inlet Plasma filter Optional Air filter Air outlet Front grille ON OFF button Signal receiver Flap Horizontal blade Louvers Vertical blades Display Indoor Units Opera...

Page 8: ...s fading replace both of the batteries 4 Use 2 AAA 1 5 volt batteries NOTE 1 Choose a suitable place where its safe easy to reach 2 Fix the holder to wall etc with the supplied screws firmly 3 Slide the remote controller inside the holder 1 Remote controller should never be exposed to direct sunlight 2 Signal transmitter receiver should always be clean for proper communication Use a soft cloth to ...

Page 9: ... ON OFF TIMER BUTTONS Used to set the time of starting and stopping operation TIME SETTING BUTTONS Used to adjust the time TIMER SET CANCEL BUTTON Used to set and to cancel the timer operation SLEEP MODE AUTO BUTTON Used to set sleep mode auto operation AIR CIRCULATION BUTTON Used to circulate the room air without cooling or heating ENERGY SAVING COOLING MODE BUTTON ROOM TEMPERATURE CHECKING BUTTO...

Page 10: ... the arrow For cooling or heating operation set the desired indoor temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS For cooling the temperature can be set within 18 C 30 C and for heating the temperature range is 16 C 30 C Set the fan speed with the remote controller You can select the fan speed in four steps low medium high and CHAOS by pressing the INDOOR FAN SPEED SELECTOR BUTTON Ea...

Page 11: ... the very humid season Auto Changeover Healthy Dehumidification Auto Operation Auto operation basically is heating or cooling function of the air conditioner But during this operation the controller changes the operation mode automatically to keep the temperature within 2 C with respect to the setting temperature Operating Instructions In this operation the actual operating mode is automatically s...

Page 12: ...nction can be used to cool the room quickly in hot summer When this function is turned on the air conditioner runs in cooling operation mode with super high fan speed and 18 C setting temperature for 30 minutes for fast and effective cooling Similarly Jet Heat function available only in some models warms up the room quickly by operating at super high fan speed and 30 C setting temperature for 30 m...

Page 13: ...ndoor FAN Speed High High High High Setting Temperature 22 C 22 C 23 C 24 C Test operation During the TEST OPERATION the unit operates in cooling mode at high speed fan regardless of room temperature and resets in 18 minutes During test operation if remote controller signal is received the unit operates as remote controller sets If you want to use this operation Press and hold the ON OFF button fo...

Page 14: ...cutive 60 minutes for a comfortable sleep Now this will be the final setting temperature as long as sleep mode is functioning NOTE 1 Time can be set only when you press the RESET BUTTON Having replacing the batteries you should press the RESET BUTTON to reset the time Press the Start Stop button 2 Press 2nd F button and check if icon is on 3 Press the TIME SETTING BUTTONS until the desired time is...

Page 15: ...mperature NOTE This feature is enabled by factory default setting but you can disable it by pressing the ON OFF button for 6 seconds The display will double blink 3 4 times To enable it press the button again for 6 seconds The display will blink 3 4 times NOTE Air Circulation Mode This function is useful in the situation of power failure When power regains after a failure this feature restore the ...

Page 16: ...TION UP DOWN LEFT RIGHT BUTTON To check the indoor temperature press button ROOM TEMPERATURE BUTTON SETTING CANCEL BUTTON EXIT BUTTON 1 4 5 7 11 10 9 8 2 3 6 13 12 Please attach the inform label inside of the door Please choose proper language depend on your country 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 MODEL PQRCVSA0 Some functions may not be operated and displayed depending on the product ty...

Page 17: ...ilters see the self explanatory diagrams for each model type Clean the filters with a vacuum cleaner or warm soapy water If dirt is not easily removed wash with a solution of detergent in lukewarm water Dry well in shade after washing and reinstall the filters back in place Allergy Free Filter Triple Filter Remove the Allergy Free Filter Triple Filter behind the air filter and expose them in direc...

Page 18: ... room when the air conditioner is in operation Keep the room temperature uniform Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room Make sure that the doors and windows are shut tight Avoid opening doors and windows as much as possible to keep the cool air in the room Clean the air filter regularly Blockages in the air filter reduce the airflow and low...

Page 19: ...e circuit breaker will trip Make sure there are no curtains blinds or furniture blocking the front of the air conditioner Clean the filter at least every 2 weeks See the Maintenance and Service section When the air conditioner is first turned on you need to allow time for the room to cool down Check for open furnace floor registers and cold air returns Make sure they are correct Check and remove s...

Page 20: ...20 Air Conditioner ...

Page 21: ...P No MFL63265201 Printed in Korea After reading this manual keep it in a place easily accessible to the user for future reference ...

Reviews: