6. White Balance Adjustment
6-1. Preparation
1) Press the APC button on the Remote control for APC ON
condition.
APC ON CONTRAST : 100
BRIGHT : 50
COLOR : 50
TINT : 0
SHARPNESS : 60
2) Set the screen for Adjustment mode by Remote Control.
6-2. Adjustment
1) Adjust the CONTRAST and BRIGHT for 40FT-1.
2) Select G-DRIVER for data Y and B-DRIVER for data X and
adjust for High Light condition. X=282, Y=288(10000+_800
K)
3) Adjust the CONTRAST and BRIGHT for 4.5FT-1.
4) Select G-BIAS for data Y and B-BIAS for data X and adjust for
Low Light condition. X=282, Y=288(10000+_800)
5) Repeat above 1) ~ 4) for good white balance.
7. FOCUS Adjustment
1) Press the APC button on the Remote Control for APC ON
condition.
2) Adjust the FOCUS control on the FBT to obtain a sharp and
clear picture.
8. Sub-Bright Adjustment
1) Input the Mono scope signal as Fig. 2.
2) Set the screen for Adjustment Mode by Remote Control.
3) Select Sub-Bright and adjust until A part is distinguishable.
- 2 -