4. TROUBLE SHOOTING
- 59 -
(5) Checking RX IQ
Re-download software and calibration again
Similar?
No
Replace U505
Yes
No
Check C518,C521
Check if there is any
Major difference
Refer to graph 4-4
U505
U101
C518
C521
C518
39p
TXIP
4
TXQN
7
TXQP
6
32
VDD2
27
RXIN
3
2
RXIP
1
RXQN
28
RXQP
TXIN
5
GND2
29
30
GND3
GND4
31
C521
39p
IP
QP
QN
IN
Test Points
Checking Flow
Waveform
Circuit Diagram
Figure 4-7
Graph 4-4
Summary of Contents for C3380