9. ENGINEERING MODE
- 109 -
9.1.7 BATTERY
1) Bat Cal :
This displays the value of Battery Calibration. The following menus are displayed in order :
BAT_LEV_4V, BAT_LEV_3_LIMIT, BAT_LEV_2_LIMIT, BAT_LEV_1_LIMIT, BAT_IDLE_LI MIT,
BAT_INCALL_LIMIT, SHUT_DOWN_VOLTAGE, BAT_RECHARGE_LMT
2) TEMP Cal :
This displays the value of Temperature Calibration. The following menus are displayed
in order : TEMP_HIGH_LIMIT, TEMP_HIGH_RECHARGE_LMT, TEMP_LOW_RECHARGE_LMT,
TEMP_LOW_LIMIT
9.1.8 Audio
This is a menu for setting the control register of Voiceband Baseband Codec chip.
Although the actual value can be written over, it returns to default value after switching off and on the
phone.
1) VbControl1 :
VbControl1 bit Register Value Setting
2) VbControl2 :
VbControl2 bit Register Value Setting
3) VbControl3 :
VbControl3 bit Register Value Setting
4) VbControl4 :
VbControl4 bit Register Value Setting
5) VbControl5 :
VbControl5 bit Register Value Setting
6) VbControl6 :
VbControl6 bit Register Value Setting
9.1.9 DAI (Digital Audio Interface)
This menu is to set the Digital Audio Interface Mode for Speech Transcoder
and Acoustic testing.
1) DAI AUDIO :
DAI audio mode
2) DAI UPLINK :
Speech encoder test
3) DAI DOWNLINK :
Speech decoder test
4) DAI OFF :
DAI mode off
9.2 RF Test [MENU 2]
9.2.1 SAR test
This menu is to test the Specific Absorption Rate.
1) SAR test on :
Phone continuously process TX only. Call-setup equipment is not required.
2) SAR test off :
TX process off
Summary of Contents for C2100
Page 1: ...Service Manual Model C2100 Service Manual C2100 P N MMBD0048201 Date April 2005 Issue 1 0 ...
Page 76: ...4 TROUBLE SHOOTING 77 4 10 KEY backlight Trouble Test Points Figure 4 21 ...
Page 104: ... 105 8 PCB LAYOUT ...
Page 105: ... 106 8 PCB LAYOUT ...
Page 113: ...10 STAND ALONE TEST 114 Figure 10 2 HW test setting Figure 10 3 Ramping profile ...
Page 117: ...Note 118 ...
Page 119: ......
Page 135: ......