background image

4

Room Air Conditioner

Safety Precautions

Two or more people must lift and
transport the product. 

• Avoid personal injury. 

Do not install the product where it will be
exposed to sea wind (salt spray) directly.

• It may cause corrosion on the product. 

Install the drain hose to ensure that the
condensed  water is drained away properly. 

• A bad connection may cause water leakage.

Keep level even when installing the
product.

• To avoid vibration or noise.

Do not install the product where the noise or
hot air from the outdoor unit could damage
or  disturb the neighborhoods.

• It may cause a problem for your neighbors

and hence dispute.

Always check for gas (refrigerant)
leakage after installation or repair of
product.

• Low refrigerant levels may cause failure of

product.

Indoor/outdoor wiring connections must  be
secured tightly and the cable should be routed
properly so that there is no force pulling the
cable from the connection terminals.

• Improper or loose connections can cause

heat  generation or fire.

Safely dispose off the packing materials. Like
screws, nails, batteries, broken things etc
after installation or svc and then tear away
and thraw away the plastic packaging bags.

• Children may play with them and cause

injury.

Make sure to check that the power cable
plug is not dirty, loose or broken  and
then only insert the plug completely.

• Dirty, loose or broken power plug can

cause electric shock or fire.

Be sure to check the refrigerant to the
used. Please read the label on the
product.

• Incorrect refrigerant used can prevent the

normal operation of the unit.

Don't use a power cord, a plug  or a
loose socket which is damaged.

• Otherwise it  may cause a fire or electrical

shock.

Do not touch , operate, or repair  the
product with wet hands. Hold the plug
by hand when taking out 

• There is risk of electric shock  or fire.

Do not place a heater or other heating
appliances near the power cable.

• There is risk of fire and electric shock.

Do not allow water to run into electric parts.
Install the unit away from water sources.

• There is risk of fire, failure of the product, or

electric shock.

Do not store or use or even allow flammable
gas or combustibles near the product. 

• There is risk of fire.

Do not use the product in a tightly
closed space for a long time. Perform
ventilation regularly.

• Oxygen deficiency could occur and hence

harm your health.

Do not open the front  grille of the product
during operation. (Do not touch the
electrostatic filter, if the unit is so equipped.) 

• There is risk of physical injury, electric

shock, or product failure.

If strange sounds, smell or smoke comes
from product.Immediately turn the
breaker off or disconnect the power
supply cable.

• There is risk of electric shock or fire.

Ventilate the product room  from time to
time when operating it together with a
stove, or heating element etc.

• Oxygen deficiency can occur and hence

harm your health.

Turn the main power off and unplug the
unit when cleaning or repairing the
product. 

• There is risk of electric shock.

When the product is not to  be used for
a long time, disconnect the power
supply plug or turn off the breaker.

• There is risk of product damage or failure, or

unintended operation.

Take care to ensure that nobody especially kids
could step on or fall onto the outdoor unit. 

• This could result in personal injury and

product damage. 

Take care to ensure that power cable could not
be pulled out or damaged during operation.

• There is risk of fire or electric shock.

Do not place ANYTHING  on the power
cable.

• There is risk of fire or electric shock.

Do not plug or unplug the power supply
plug to turn the unit ON/OFF .

• There is risk of fire or electric shock.

When flammable gas leaks, turn off the
gas and open a window for ventilation
before turn the product on. 

• Do not use the telephone or turn switches

on or off. There is risk of explosion or fire.

For inner cleaning, contact an
Authorized Service Center or a dealer. 
Do not use harsh detergent that causes
corrosion or damage on the unit.

• Harsh detergent may also cause failure of

product, fire, or electronic shock.

Summary of Contents for C12LHR

Page 1: ...ur set and retain it for future reference OWNER S MANUAL AIR CONDITIONER The equipment complies with requirements of the Technical Regulation in terms of restrictions for the use of certain dangerous substances in electrical and electronic equipment ENGLISH РУССКИЙ ЯЗЫК O ZBEK TILI ...

Page 2: ...o not play with the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts A Safety Precautions 3 B Electrical Safety 6 Temporary Use of an Adapter 6 Temporary Use of an Extension Cord 6 Symbols used in this Manual 6 C Product Introduction 7 Indoor Units 7 Operation Indication Lamps 8 Outdoor Unit ...

Page 3: ... securely There is risk of fire or electric shock due to dust water etc Use the correctly rated breaker or fuse There is risk of fire or electric shock Do not modify or extend the power cable If the power cable or cord has scrathes or skin peeled off or deteriorated then it must be replaced There is risk of fire or electric shock For installation removal or reinstall always contact the dealer or a...

Page 4: ...ric shock Do not allow water to run into electric parts Install the unit away from water sources There is risk of fire failure of the product or electric shock Do not store or use or even allow flammable gas or combustibles near the product There is risk of fire Do not use the product in a tightly closed space for a long time Perform ventilation regularly Oxygen deficiency could occur and hence ha...

Page 5: ...y If the refrigerant gas leaks during the installation ventilate the area immediately Otherwise it can be harmfull for your health Dismantling the unit treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards Replace the all batteries in the remote control with new ones of the same type Do not mix old and new batteries or different types of...

Page 6: ... Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection To disconnect the power cord from the adapter use one hand on each to avoid damaging the ground terminal Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage Never use the appliance with a broken adapter We strongly discourage the us...

Page 7: ...play panel LED indicators Signal receiver Front panel Air discharge Power cord Plasma filter Air filter Air inlet Plasma filter Optional Air filter Air outlet Front grille ON OFF button Signal receiver Grille tab Flap Horizontal blade Louvers Vertical blades Signal receiver Front Panel Air Discharge Power Cord Air Filter Plasma Filter ON OFF button Art Cool Type Wide Display panel LED indicators S...

Page 8: ...ing heating Dehumidification Mode On Off Lights up during the system operation error code and auto restart setting Sleep mode Energy Saving Cooling Mode Lights up during sleep mode auto operation Plasma The function illustrates its dynamic mode by using a multiple lighting system Each model has a different Operation Indication Lamp Lights up during Energy Saving Cooling Mode Operation Energy savin...

Page 9: ...ller towards the unit to operate it There should not be any blockage in between NOTE Owner s Manual 9 Operating Instructions How to insert the Batteries Wireless Remote Controller Maintenance 1 Remove the battery cover by pulling it according to the arrow direction 2 Insert new batteries making sure that the and of battery are installed correctly 3 Reattach the cover by sliding it back into positi...

Page 10: ... speed in cooling mode 6 CHAOS SWING BUTTON Used to stop or start louver movement and set the desired up down airflow direction 7 TIMER AND TIME SETTING BUTTON Used to set the time of starting and stopping operation 8 TIME SETTING BUTTONS Used to adjust the time 9 TIMER SET CLEAR BUTTON Used to set and to cancel the timer operation 10 SLEEP MODE AUTO BUTTON Used to set sleep mode auto operation 11...

Page 11: ...o Changeover Heat Pump Model For cooling or heating operation set the desired indoor temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS For cooling the temperature can be set within 18 C 30 C and for heating the temperature range is 16 C 30 C Set the fan speed with the remote controller You can select the fan speed in four steps low medium high and CHAOS by pressing the INDOOR FAN SPEED ...

Page 12: ...temperature within 2 C with respect to the setting temperature Operating Instructions In this operation mode the actual setting temperature and the fan speed are automatically set by the electronic control logic based on the current room temperature If you feel hot or cold press the temperature setting buttons respectively for more cooling or heating effect NOTE You cannot set the actual setting t...

Page 13: ...ble only in some models warms up the room quickly by operating at super high fan speed and 30 C setting temperature for 60 minutes Plasma filter is a technology developed by LG to get rid of microscopic contaminants in the intake air by generating a plasma of high charge electrons This plasma kills and destroys the contaminants completely to provide clean and hygienic air You can activate this ope...

Page 14: ...t 2 Open the door of the remote controller Select cooling operation or healthy dehumidification operation 3 Press the ENERGY SAVING COOLING MODE BUTTON 4 To cancel the energy saving cooling mode press the ENERGY SAVING COOLING MODE BUTTON again and unit will operate in previous mode Cooling or healty dehumidification mode Heat pump Model Cooling Model Room Temp 24 C 21 C Room Temp 24 C Room Temp 2...

Page 15: ...ng temperature as long as sleep mode is functioning NOTE If you wish to cancel all timer setting press the CLEAR ALL BUTTON If you wish to cancel each timer setting press the TIMER BUTTON to turn timer sleep on or off as you want And then press the SET CLEAR BUTTON aiming the remote controller at the signal receptor The timer lamp on the air conditioner and the display will go off 1 Press the TIME...

Page 16: ...s algorithm to distribute the air in the room evenly and at the same time to make the human body feel most comfortable as if enjoying natural breeze Manually moving the vertical air flow direction louver by hand could damage the mechanism When the unit is shut off the up down airflow direction louver will close the air outlet vent of the system The Chaos Swing may not run correctly during sleep mo...

Page 17: ...n shade after washing and reinstall the filters back in place Plasma Filters The plasma filters behind the air filter should be checked and cleaned once in every 3 months or more often if necessary To remove the filters see the self explanatory diagrams for each model type Clean the filters with a vacuum cleaner If it is dirty wash it with water and dry well in shade an install back in place Deodo...

Page 18: ...sma filter Dry it completely in the shade after leaning Then set a plasma filter and a filter orderly Put the hook of front panel onto the hanger in order to close the front panel 4 Art Cool Type Wide The procedure of removal of filters is same as in Art Cool Type1 model as shown above Don t touch this plasma filter within 10 seconds after opening the inlet grille it may cause an electric shock Fr...

Page 19: ...r Front panel 5 Deluxe Type 1 Open the upside of the panel and lift it up as shown The hooks of the panel will come off Remove the air filters Then pull out the plasma filter After cleaning and drying well reinstall the filters in their original position Front panel Panel hook Plasma filter How to use the front panel 1 Front panel closing Move the link upward and close the front panel 2 Front pane...

Page 20: ...en take off a protective tape attached at the mat 6 Place the picture photograph between the exited picture and mat Recommended size of a photo picture 450mm x 450mm 7 Cover mat and press down with hand s until contacting closely 8 Slide the photo graph drawing requested under both hanger parts as following and fix them Press the front panel lightly to close 9 Push both links of lower part of pane...

Page 21: ...a situation Do not overcool the room This is not good for the health and wastes electricity Keep blinds or curtains closed Do not let direct sunshine enter the room when the air conditioner is in operation Keep the room temperature uniform Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room Make sure that the doors and windows are shut thight Avoid open...

Page 22: ...er will trip Make sure there are no curtains blinds or furniture blocking the front of the air conditioner Clean the filter at least every 2 weeks See the Maintenance and Service section When the air conditioner is first turned on you need to allow time for the room to cool down Check for open furnace floor registers and cold air returns Make sure they are correct Check and remove such source or t...