3. INSTALLATION
3.1 SELECT THE BEST LOCATION
1.To prevent vibration and noise, make sure the unit
in installed securely and firmly.
2.Install the unit where the sunlight does not shine
directly on the unit.
3.There should be no obstacle, such as a
fence or wall, within 50cm from the back of the
cabinet because it will prevent heat radiation of the
condenser.
Restriction of outside air will greatly reduce the
cooling efficiency of the air conditioner.
4.Install the unit a little obliquely outward not to leak
the condensed water into the room (about 10 ~
15mm or 1/4 bubble with level).
5.Install the unit with the bottom about 70 ~ 150cm
above the floor level.
3.2 CHECK OF INSTALLATION
The setting conditions must be checked prior to
initial starting.
The undermentioned items are especially important
checking points when the installation is finished.
1. Grounding wire (Green or Green and Yellow) is
provided in the power cord. The green wire must
be grounded.
2. Connect to a single-outlet 15AMP circuit.
3. To avoid vibration or noise, make sure the air
conditioner is installed securely.
4 Avoid placing furniture or draperies in front of the
air inlet and outlet.
The air conditioner must be installed level or tilted
slightly to the outside for proper water drainage.
On exceptionally hot and humid days the air
conditioner may drain condensation through
overflow.
If the air conditioner is used in hot and a high
humidity zone, exchange the
HOLE RUBBER
for the
DRAIN PIPE.(See figure 18, figure 19.)
All side louvers of the cabinet must remain
exposed to the outside of the structure.
10~15mm
Over 50cm
HEAT
RADIATION
FENCE
AWNING
FOAM
COOLED
AIR
70-150cm
BASE PAN
HOLE RUBBER
DRAIN PIPE
1
BOTTOM
2
BASE PAN
BOTTOM
Figure 18
Figure 19
Figure 17
CAUTION
3.3. HOW TO DRAIN (When using drain pipe)