6-3 ANOTHER ELECTRIC COMPONENTS
t
Cooling is impossible
Compressor
doesn’t run.
Running state of
Compressor is poor.
Check a starting
voltage.
Check if current flows to
the following
components.
a. Thermistor
b. Starting devices
c. OLP
d. Compressor coil
e. Circuit Parts
Low voltage.
Poor contacting.
Shorted or broken.
Poor contacting
or shorted.
Coil shorted.
Poor contacting
or shorted.
Poor contacting
and broken.
Shorted.
Lack of capacity.
Coil of motor
Compressor.
Replace
the compressor.
Replace
each component.
Raise the voltage.
Replace
each component.
Cause.
Check if current flows
to starting devices.
Check current flowing
in sub-coil of
Compressor.
Check capacity of OLP.
The items described
above are normal.
t
Cooling ability is poor
Fan motor
doesn’t run.
Much frost are sticked
to the EVAPORATOR.
Poor contacting.
Coil is shorted.
Shorted.
Replace
each component.
Replace
each component.
Replace
each component.
Check current flowing
in door S/W.
Check current flowing
in the Fan Motor.
Check current flowing
of the following
components.
¥ Def. Sensor
¥ FUSE-M
Check current flowing
of the following
components.
¥ Heater plate
¥ Heater cord
Summary of Contents for B712Y*B
Page 36: ...7 5 2 REPLACEMENT PARTS LIST 36 ...
Page 37: ... 37 ...
Page 38: ...7 5 3 PWB ASS Y DISPLAY AND PARTS LIST 38 ...
Page 39: ... 39 7 5 4 PWB ASS Y DISPLAY I MICOM AND PARTS LIST ...
Page 40: ... 40 7 5 5 V LED DISPLAY PART LIST ...
Page 41: ...7 6 PWB DIAGRAM 41 ...
Page 42: ... 42 ...
Page 44: ... 44 149D 155J 149B 120 118 119 138 120 110 111 149B 405A 140A 133 405C 405C 404A ...