CONVENIENT FUNCTIONS
27
ENGLISH
Pressure compensation function (for Round Type)
If you use additional pipe to install the cooling operation, this function can compensate the target
of pressure by setting DIP switch.
* Pressure compensation function is release at initial state as standard.
* This function is used only if the length of pipe > 25 m, and be sure not to exceed the maximum
length of pipe. (It can be different depend on the model.)
Set the DIP switch as follow after shutting the power source down.
1
Open the side panel or top cover of outdoor unit.
2
Set the DIP switch like below image.
For setting pressure compensation function
CONVENIENT FUNCTIONS
U4: 36 kBtu/h
U3: 50 kBtu/h
Setting/Display/
Communication
status
Press tact switch
Key letter
for each data
Indicating data
for 0.5
0.5 off
0.5 off
0.5 off
0.5 off
0.5 off
0.5 off
0.5 off
0.5 off
Hz
Current
Voltage
DC Link
Press tact switch
Press tact switch
Press tact switch
Press tact switch
3
7 segments indicate each status and data like below image.
(Unit : sec)
Summary of Contents for ATUW36GYLP0