Installer Setting - Setting Address of Central Control

Installer Setting - Checking Address of Central Control

1

With the FUNC. button pressed, press the RESET button.

2

Press the ON/OFF button toward the indoor unit 1 time, and the indoor unit will display the
set address in the display window.

• The address display time and method can differ by the indoor unit type.

3

Reset the remote controller to use the general operation mode.

1

With the MODE button pressed, press the
RESET button.

2

By using the temperature setting button,
set the indoor unit address.

• Setting range : 00 ~ FF

3

After setting the address, press the
ON/OFF button toward the indoor unit 1
time.

The indoor unit will display the set address
to complete the address setting.

• The address display time and method

can differ by the indoor uint type.

5

Reset the remote controller to use the
general operation mode.

RESET button

1,MFL61971240,영영  2017. 6. 19.  영영 1:54  Page 17

Summary of Contents for ATNQ18GPLE6

Page 1: ...e performed in accordance with the national wiring standards by authorized personnel only Please retain this installation manual for future reference after reading it thoroughly Ceiling Cassette ATNQ18GPLE6 ATNQ24GPEL6 ATNQ30LNLE6 ATNQ36GNLE6 ATNQ36LNLE6 ATNQ48GMLE6 ATNQ48LMLE6 ENGLISH BAHASA INDONESIA Rev 05 12T18 MFL61971240 I 15 LEI13 02944 0717 ...

Page 2: ...for many hours Clean the air filter once every 2 weeks Dust and impurities collected in the air filter may block the air flow or weaken the cooling dehumidifying functions For your records Staple your receipt to this page in case you need it to prove the date of purchase or for warranty purposes Write the model number and the serial number here Model number Serial number You can find them on a lab...

Page 3: ...sponsible for their safety Installation Do not install duct through disassemble or repare the product yourself This product can not install duct Do not use a defective or underrated circuit breaker Use this appliance on a dedicated circuit There is risk of fire or electric shock For electrical work contact the dealer seller a qualified electrician or an authorized service center Do not disassemble...

Page 4: ...d space for a long time Oxygen deficiency could occur When flammable gas leaks turn off the gas and open a window for ventilation before turn the product on Do not use the telephone or turn switches on or off There is risk of explosion or fire If strange sound smell or smoke comes from product turn the breaker off or disconnect the power supply cable There is risk of electric shock or fire Stop op...

Page 5: ...e plastic parts of the product Do not touch the metal parts of the product when removing the air filter They are very sharp There is risk of personal injury Do not step on or put anyting on the product outdoor units There is risk of personal injury and fail ure of product Always insert the filter securely Clean the filter every two weeks or more often if necessary A dirty filter reduces the effici...

Page 6: ...nnection 12 INSTALLATION OF DECORATIVE PANEL ACCESSORY 14 TEST RUNNING 15 INSTALLATION INSTRUCTIONS 15 Installer Setting How to enter installer setting mode 16 Installer Setting Installer Setting Code Table 17 Installer Setting Setting Address of Central Control 17 Installer Setting Checking Address of Central Control TABLE OF CONTENTS 1 MFL61971240 영영 2017 6 19 영영 1 54 Page 6 ...

Page 7: ...m the wall ceiling or other obstacles The indoor unit must keep the maintenance space Unit mm inch Ceiling Ceiling Board Ceiling Board H 1000 39 3 8 or more 500 19 11 16 or more 500 19 11 16 or more 300 11 13 16 or more Floor 10 13 32 or more Please use the corrugated cardboard on the bottom of packing as installation sheet When using the bottom sheet please use it after separating the installatio...

Page 8: ...location 1 Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated These may cause heat exchange efficiency reduction or water drops drain pump mal function In these cases take the following actions Make sure that ventilation fan is enough to cover all noxious gases from this place Ensure enough distance from the cook ing room to install the air conditi...

Page 9: ...ll slightly tilted to the outdoor side using a Ø 65 2 9 16 mm inch hole core drill Wall Indoor Outdoor Slope gradient for drain Should be 1 50 1 100 CAUTION Tighten the nut and bolt to prevent unit falling Upward routing not allowed 1 50 1 100 MAX 800 31 1 2 Unit mm inch Unit mm inch 800 31 1 2 or less Clamp metal attached Drain hose attached Drain raising pipe 300 11 13 16 mm or less 300 11 13 16...

Page 10: ...ioner has been tested accord ing to the KS Standard Conditions with Mist and confirmed that there is not any default However if it is operated for a long time in high humid atmosphere dew point tempera ture more than 23 C water drops are liable to fall In this case add heat insulation mate rial according to the following procedure Indoor unit Thermal insulator accessory Fastening band accessory Re...

Page 11: ... should be selected according to the fol lowing specifications If the supply cord is damaged it must be replaced by a special cord or assembly available from the manufacturer of its service agent NORMAL CROSS SECTIONAL AREA 0 75 mm2 20 25 32 mm inch 35 1 3 8 5 3 16 mm inch GN YL 10 13 32 3 1 8 mm inch Power wire r Round pressure terminal Connect same thickness wiring to both sides It is forbidden ...

Page 12: ...over 3 Fit the panel on the unit by inserting hooks as shown in picture 5 Fit the corner covers 4 Insert two screws on diagonal corners of panel Do not tighten the bolts completely The fixing screws are included in the indoor unit box Check the alignment of panel with the ceil ing Height can be adjusted using hanging bolts as shown in picture Insert the other two screws and tighten all screws com ...

Page 13: ...tor CN VANE 1 2 8 Close the cover for control box 9 Install the air inlet grille and Filter on the panel Air conditioner unit Decorative panel Fit the insulator this part and be careful for cool air leakage Good example Ceiling board Ceiling board Decorative panel Air Cool air leakage no good Bad example Air conditioner unit CAUTION Install certainly the decorative panel Cool air leakage causes sw...

Page 14: ...ion of air adequate Is the draining smooth Is the heat insulation complete refrigerant and drain piping Is there any leakage of refrigerant Is the remote controller switch operated Is there any faulty wiring Are not terminal screws loosened M4 118 N cm 12 kgf cm 87 klbf in M5 196 N cm 20 kgf cm 145 klbf in M6 245 N cm 25 kgf cm 181 klbf in M8 588 N cm 60 kgf cm 434 klbf in To cancel the test run p...

Page 15: ...the detail function of the remote controller If the installer setting mode is not set correctly it can cause problems to the product user injury or property damage This must be set by an certificated installer and any installation or change that is carried out by a non certificated person should be responsible for the results In this case free service cannot be provided RESET button Refer to the I...

Page 16: ...height setting Group Control This function is only for group control Please don t set this function in case of non group control After setting Group Control of the product turn off the power then turn it back on after 1 minute Installer Setting Installer Setting Code Table Installer Setting Code Table No Function Function Code Setting Value Remote Controller LCD 1 Ceiling Height Selection 1 1 Stan...

Page 17: ...e indoor unit type 3 Reset the remote controller to use the general operation mode 1 With the MODE button pressed press the RESET button 2 By using the temperature setting button set the indoor unit address Setting range 00 FF 3 After setting the address press the ON OFF button toward the indoor unit 1 time 4 The indoor unit will display the set address to complete the address setting The address ...

Page 18: ...1 MFL61971240 영영 2017 6 19 영영 1 54 Page 18 ...

Page 19: ... www lg com Bacalah panduan pemasangan ini secara menyeluruh sebelum memasang produk Pekerjaan pemasangan harus dilakukan sesuai dengan standar perkabelan nasional setempat dan hanya oleh petugas resmi saja Simpanlah panduan pemasangan untuk referensi di masa mendatang setelah membaca secara menyeluruh BAHASA INDONESIA I 15 LEI13 02944 0717 ...

Page 20: ...ama berjam jam Bersihkan filter udara setiap 2 minggu Debu dan kotoran yang terkumpul di dalam filter dapat menyumbat aliran udara atau melemahkan fungsi pendinginan Pengatur kelembapan Untuk data Anda Staples tanda terima ke halaman ini apabila suatu saat Anda memerlukan bukti tanggal pembelian atau jika ada masalah dengan garansi Tulis nomor model dan nomor seri di sini Nomor model Nomor seri An...

Page 21: ...t mental atau orang yang kurang atau tidak memiliki pengalaman dan pengetahuan kecuali apabila mereka diawasi atau diberi petunjuk penggunaan oleh orang yang bertanggung jawab atas keselamatan mereka Pemasangan Jangan melakukan sendiri pemasangan saluran melalui pembongkaran atau perbaikan produk Produk ini tidak dapat dipasang saluran Jangan menggunakan sekering yang rusak atau di dengan rating r...

Page 22: ...yang mudah terbakar di dekat produk Berisiko kebakaran atau kerusakan produk Jangan menggunakan produk di tempat yang tertutup rapat dalam waktu yang lama Dapat terjadi kekurangan oksigen Jika terjadi kebocoran gas yang mudah terbakar matikan aliran gas dan buka jendela untuk ventilasi sebelum menghidupkan produk Jangan menggunakan telepon atau menggunakan sakelar untuk menghidupkan atau mematikan...

Page 23: ...g terbuat dari plastik Jangan menyentuh bagian produk yang terbuat dari logam saat melepas filter udara Bagian tersebut sangat tajam Terdapat risiko cedera badan Jangan menginjak atau meletakkan apa pun di atas produk unit luar ruangan Terdapat risiko cedera badan dan kerusakan produk Selalu pasang filter dengan kencang Bersihkan filter setiap dua minggu atau lebih sering bila perlu Filter yang ko...

Page 24: ...10 Sambungan Kabel 12 PEMASANGAN PANEL DEKORATIF AKSESORI 14 UJI COBA 15 PETUNJUK PEMASANGAN 15 Pengaturan Installer Cara memasuki mode pengaturan installer 16 Pengaturan Installer Tabel Kode Pengaturan Installer 17 Pengaturan Installer Penetapan Pengaturan Kontrol Pusat 17 Pengaturan Installer Memeriksa Tetapan Kontrol Pusat DAFTAR ISI 2 MFL61971240 인인인인인 2017 6 19 인인 1 53 Page 6 ...

Page 25: ...iliki ruang untuk pemeliharaan Satuan mm inci Langit langit Papan langit langit ternit Papan langit langit ternit H 1000 39 3 8 atau lebih 500 19 11 16 atau lebih 500 19 11 16 atau lebih 300 11 13 16 atau lebih Lantai 10 13 32 atau lebih Gunakan kardus bergelombang dari bagian bawah kemasan sebagai lapisan pemasangan Bila menggunakan lapisan bawah gunakan ini setelah memisahkan lembar pemasangan d...

Page 26: ...si pemasangan berikut ini 1 Tempat tempat seperti restoran dan dapur di mana terdapat uap minyak dan tepung Ini dapat menyebabkan berkurangnya efisiensi pertukaran panas atau air menetes kerusakan pompa pembuangan Dalam kondisi ini lakukan tindakan berikut Pastikan bahwa kipas ventilasi sudah cukup untuk mencakup semua gas beracun dari tempat ini Beri jarak yang cukup dari dapur untuk memasang AC ...

Page 27: ...engah berdiameter Ø 65 2 9 16 mm inci Dinding Dalam ruangan Luar ruangan Kemiringan berangsur untuk saluran pembuangan Harus 1 50 1 100 HATI HATI Kencangkan mur dan baut untuk mencegah unit terjatuh Tidak diperbolehkan mengarah ke atas 1 50 1 100 MAKS 800 31 1 2 Satuan mm inci Satuan mm inci 800 31 1 2 mm atau kurang Logam klem terpasang Selang pembuangan terpasang Pipapembuangannaik 300 11 13 16 ...

Page 28: ...ni telah diuji menurut KS Standard Conditions with Mist Kondisi Standar KS dengan Embun dan dipastikan tidak ada kerusakan Namun jika dioperasikan dalam waktu lama di lingkungan yang sangat lembab suhu titik embun lebih dari 23 C tetesan air akan terjatuh Dalam kondisi ini tambahkan bahan insulasi panas menurut prosedur berikut ini Unit dalam ruangan Insulator panas aksesoris Pita pengencang akses...

Page 29: ...us dipilih sesuai dengan spesifikasi berikut ini Kabel suplai yang rusak harus diganti dengan rakitan atau kabel khusus yang tersedia dari produsen agen servisnya 20 25 32 mm inci 35 1 3 8 5 3 16 mm inci GN YL 10 13 32 3 1 8 mm inci LUAS PENAMPANG MELINTANG NORMAL 0 75 mm2 Kabel listrik Terminal tekanan lingkaran Sambungkan kabel dengan ketebalan yang sama untuk kedua sisi Dilarang untuk menyambun...

Page 30: ...asukkan kait seperti yang ditunjukkan pada gambar 5 Pasang penutup sudut 4 Masukkan dua sekrup pada sudut diagonal panel Jangan kencangkan baut sepenuhnya Sekrup pengencang disertakan bersama kotak unit dalam ruangan Periksa kesejajaran panel dengan langit langit Ketinggian dapat disesuaikan menggunakan baut penggantung seperti yang ditunjukkan pada gambar Masukkan dua sekrup lagi dan kencangkan s...

Page 31: ...ANE 1 2 8 Tutup penutup kotak kontrol 9 Pasang kisi kisi saluran masuk udara dan Filter pada panel Unit AC Panel dekoratif Pasang insulator komponen ini dan berhati hatilah terhadap kebocoran udara Contoh yang baik Papan langit langit ternit Papan langit langit ternit Panel dekoratif Udara Kebocoran udara dingin tidak baik Contoh yang buruk Unit AC HATI HATI Pasang panel dekoratif dengan kencang U...

Page 32: ...Apakah insulasi panas sudah lengkap refrigeran dan pipa pembuangan Apakah ada kebocoran refrigeran Dapatkah tombol remote control dioperasikan Adakah kesalahan pemasangan kabel Apakah sekrup terminal tidak longgar M4 118 N cm 12 kgf cm 87 klbf in M5 196 N cm 20 kgf cm 145 klbf in M6 245 N cm 25 kgf cm 181 klbf in M8 588 N cm 60 kgf cm 434 klbf in Untuk membatalkan pengujian tekan sembarang tombol ...

Page 33: ...pkan fungsi remote control secara rinci Jika mode pengaturan installer tidak ditetapkan dengan benar dapat menyebabkan masalah pada produk cedera pengguna atau kerusakan properti Mode ini harus ditetapkan oleh installer resmi dan pemasangan atau perubahan yang dilakukan oleh pihak tak resmi bukan merupakan tanggung jawab kami Dalam kasus seperti ini servis gratis tidak akan disediakan Tombol RESET...

Page 34: ...uai dengan pengaturan ketinggiannya Kontrol Grup Fungsi ini hanya untuk kontrol grup Jangan mengatur fungsi ini jika bukan kontrol grup Setelah mengatur Kontrol Grup produk matikan daya dan nyalakan lagi setelah 1 menit Pengaturan Installer Tabel Kode Pengaturan Installer Tabel Kode Pengaturan Installer No Fungsi Kode Fungsi Nilai Pengaturan LCD Remote control 1 Pilihan Ketinggian Langit Langit 1 ...

Page 35: ... 3 Reset remote control untuk menggunakan mode pengoperasian umum 1 Bersamaan dengan menekan tombol MODE tekan tombol RESET 2 Dengan menggunakan tombol pengaturan suhu atur tetapan unit dalam ruangan Kisaran pengaturan 00 FF 3 Setelah menetapkan alamat tekan tombol HIDUP MATI ke arah unit dalam ruangan 1 kali 4 Unit dalam ruangan akan menampilkan tetapan yang diatur untuk menyelesaikan pengaturan ...

Page 36: ...r oleh PT LG ELECTRONICS INDONESIA GANDARIA 8 OFFICE TOWER LT 29 BC 31 ABCD JL SULTAN ISKANDAR MUDA KEBAYORAN LAMA JAKATA SELATAN 12240 DKI JAKARTA RAYA INDONESIA 2 MFL61971240 인인인인인 2017 6 19 인인 1 53 Page 18 ...

Reviews: