- 86 -
13. DESCRIPTION OF FUNCTION & CIRCUIT OF MICOM
13-1 FUNCTION
13-1-1 Function
- When the appliance is plugged in, default set values are 37
for Refrigerator and 0
for freezer.
- You can adjust Refirgerator and freezer control temperature by pressing ADJUST button on display
1. When the power is initially applied or restored after a power failure, it is set to Control temperature
Previously.
2. Top display is turned on when the door is left open. dispenser panel is always turned on the water, cube,
crush, lock Icon that has been selected.
13-1-3 Lock function
1. When refrigerator is firstly turned on, the buttons are not locked.
“Lock” is deactivated.
2. To lock the display, the control panel, press and hold the lock
buttons for 3 seconds, “Lock” is activated.
3. The Lock button is the only control feature that remains active
in the locked state. The buzzer sound, other control buttons and
are deactivated.
4. To release from the locked state, press and hold the Lock button again for 3 seconds.
Ex) In Selecting
“LOCK”
Ex) In Selecting
“LOCK” again
13-1-2 How to Toggle the Display between
&
1. The initial setting is
and the display temperature made can be changed from
to
or
to
by
pressing and holding the FRZ TEMP and the REF TEMP keys at the same time for over 5 seconds.