background image

12

Air Conditioner

During Healthy Dehumidification Operation

If you select the dehumidification mode on the OPERATION MODE 
SELECTION BUTTON, the product starts to run the dehumidification function.
It automatically sets the room temperature and airflow volume to the best
condition for dehumidification, based on the sensed current room temperature.

In this case, however, the setting temperature is not displayed on the remote 
controller and you are not able to control the room temperature either.

During the healthy dehumidification function, the fan speed is automatically set
according to the optimization algorithm responding to the current room
temperature status, so that the room condition is kept healthy and comfortable
even in the very humid season.

Operating Instructions

<For Cooling Model>

The temperature and fan speed are automatically set by the electronic controls based on the

actual room temperature. 

If you feel hot or cold, press TEMPERATURE SETTING buttons for more cooling or heating effect.
You cannot switch the indoor fan speed. It has already been set by the Auto Operation Mode rule.

Auto Operation(Optional)

Healthy Dehumidification Operation

MODE

This operation is basically heating or cooling function of the air 
conditioner. But  during this operation the controller changes the 
operation mode automatically to keep the temperature within 
±2°C with respect to the setting temperature.

Auto Changeover Operation (Optional)

MODE

TEMP

 Code Feel
 2 

Cold

 1 

Slightly cool

 0 

Neutral

 -1 

Slightly warm

 -2 

Warm

 Please select the code

  as per your requirement.

You can set desired temperature and indoor fan speed.
Setting Temp. Range : 18~30°C.

: You can not set the actual setting temperature and the fan speed in

this operation mode ,But  you can use the Auto swing in this
operation. If the system is not operating as desired,switch manually
to another mode 

NOTE

<For Heating Model>

Summary of Contents for ASNW07GB1U0

Page 1: ...this owner s manual carefully and thoroughly before installing and operating your room air conditioner Please retain this owner s manual for future reference after reading it thoroughly Type Wall Mounted ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH πÃÕ PORTUGUÊS NEDERLANDS POLSKI MAGYAR ...

Page 2: ...wer cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts A Safety Precautions 3 B Electrical Safety 6 Temporary Use of an Adapter 6 Temporary Use of an Extension Cord 6 Symbols used in this Manual 6 C Product Introduction 7 Indoor Units 7 Operation Indication Lamps 7 Outdoor Unit 7 D Operating Instructions 8 How to insert the ...

Page 3: ...urely There is risk of fire or electric shock due to dust water etc Use the correctly rated breaker or fuse There is risk of fire or electric shock Do not modify or extend the power cable If the power cable or cord has scrathes or skin peeled off or deteriorated then it must be replaced There is risk of fire or electric shock For installation removal or reinstall always contact the dealer or an Au...

Page 4: ...ilure If strange sound smell or smoke comes from product Immediately turn the breaker off or disconnect the power supply cable There is risk of electric shock or fire Ventilate the product room from time to time when operating it together with a stove or heating element etc Oxygen deficiency can occur and hence harm your health Turn the main power off and unplug the unit when cleaning or repairing...

Page 5: ...used in the system If air enters the refrigerant system an excessively high pressure results causing equipment damage or injury If the refrigerant gas leaks during the installation ventilate the area immediately Otherwise it can be harmfull for your health Dismantling the unit treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards Replace...

Page 6: ...nuine adapter available from most local hardware stores Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection To disconnect the power cord from the adapter use one hand on each to avoid damaging the ground terminal Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage Never use the applia...

Page 7: ...sma lamp lights up at the same time Premium type doesn t have Plasma lamp Operation lamp Signal Receiver ON OFF button Allergy free filter Triple filter Air inlet ON OFF button Eco Eye sensor Air outlet Horizontal vane Vertical louver Plasma filter Air filter Front grille Premium type Rational type Operation lamp Signal receiver Signal receiver Signal receiver Air inlet Plasma filter Air filter Fr...

Page 8: ...arrow direction 2 Insert new batteries making sure that the and of battery are installed correctly 3 Reattach the cover by sliding it back into position 1 Always use replace both batteries of same type 2 If the system is not to be used for a long time remove the batteries to save their working life 3 If the display screen of remote controller starts fading replace both of the batteries 4 Use 2 AAA...

Page 9: ...ntal airflow direction AUTO CLEAN BUTTON Used to set auto clean ENERGY SAVING COOLING BUTTON Used to save Energy ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature TIMER BUTTON before adjusting Used to set the current time and the time of starting stopping TIME ADJUSTING BUTTONS Used to adjust the time TIMER SET CLEAR BUTTON after adjusting Used to set and to cancel the timer oper...

Page 10: ...geover Healthy Dehumidification Operation Heating Operation Only heat pump Air Circulation Signal transmitter Operation Mode Optional1 Optional2 Optional3 SLEEP MODE AUTO BUTTON Used to set sleep mode auto operation ECO EYE BUTTON Used to set and to cancel the timer operation JET COOL MOISTURE COOLING BUTTON Used to start or stop the speed cooling and Moisture Cooling The Jet Cool operates fan in ...

Page 11: ...of the arrow For cooling or heating operation set the desired indoor temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS For cooling the temperature can be set within 18 C 30 C and for heating the temperature range is 16 C 30 C Set the fan speed with the remote controller You can select the fan speed in six steps low medium low medium medium high high and natural wind by pressing the INDO...

Page 12: ...tically set by the electronic controls based on the actual room temperature If you feel hot or cold press TEMPERATURE SETTING buttons for more cooling or heating effect You cannot switch the indoor fan speed It has already been set by the Auto Operation Mode rule Auto Operation Optional Healthy Dehumidification Operation MODE This operation is basically heating or cooling function of the air condi...

Page 13: ...lter is a technology developed by LG to get rid of microscopic contaminants in the intake air by generating a plasma of high charge electrons This plasma kills and destroys the contaminants completely to provide clean and hygienic air Plasma purification operation can be started by pressing the PLASMA BUTTON on the remote controller Repressing it will deactivate the operation This features can be ...

Page 14: ... COOLING MODE BUTTON again and unit will operate in previous mode Cooling mode Display Luminosity Optional The unit display Luminosity can be adjusted by using the remote controller Open the cover of the remote controller and press the LED LUMINOSITY button Display LED will be dark Press the button again to set bright display The order of 100 50 LUMINOSITY is repeated whenever you press the button...

Page 15: ...he final setting temperature as long as sleep mode is functioning NOTE Sleep Mode Operation Press the Timer button once to set on the Reserved On Press the Timer button twice to set the Reserved Off 1 Press the Time Setting buttons until the desired time is set The order of a m and p m hour minute is repeated whenever you press the button By pressing the button you can set the desired time 2 Press...

Page 16: ...utton once more during Auto Swing at the direction of airflow you want Press the Horizontal Airflow Direction button once more during Full Auto Swing at the direction of airflow you want 1 Step 2 Step 3 Step 4 Step 5 Step Left Auto Swing Right Auto Swing Full Auto Swing STOP Manually moving the Horizontal Vane or Vertical Louvers by hand could damage the mechanism When the unit is shut off the the...

Page 17: ...de with super high fan speed and 18 C setting temperature for 30 minutes for fast and effective cooling Similarly jet heat function available only in some models warms up the room quickly by operating at super high fan speed and 30 C setting temperature for 30 minutes You can activate this operation by pressing the JET COOL BUTTON To change from jet cool mode to high fan speed cooling mode press t...

Page 18: ...ring curtains sunlight reflected light etc are also mistakenly detected Energy Saving mode can be occurred because of sensing uncorrectly depending on the thickness of clothes It goes into Energy Saving mode if there are no people in the detecting area for 20 minutes Energy Saving mode set setting temperature maximum 2 C during cooling and maximum 2 C during heating When surrounding temperature is...

Page 19: ...Area 2 Area 3 For example Area 1 Area 2 Direct Airflow Indirect Airflow Energy Saving mode Detecting Range The air conditioner will go into Energy saving mode after 20 minutes the air conditioner doesn t detect people Operating Instructions In case two or more people are detected in the different area it changes auto swing mode People are detected in the boundary between Area1 and Area2 it chages ...

Page 20: ...ontroller sets If you want to use this operation Press and hold the ON OFF button for 3 5 seconds then the buzzer sound 1 beep If you want to stop the operation re press the button Open the front panel Press the ON OFF button So you can operate the air conditioner Lift up the front panel after approximately 25 seconds Fold the supporter Close the front panel Press the front panel as shown until he...

Page 21: ...l blink 6 times To enable it press the button again for 6 seconds The unit will beep twice and the blue lamp will blink 4 times NOTE This function is useful in the situation of power failure When power regains after a failure this feature restore the previous operating condition and the air conditioner will run in the same settings Auto Restart Function ON OFF button ON OFF button Premium type Rat...

Page 22: ...he filters see the self explanatory diagrams for each model type Clean the filters with a vacuum cleaner or warm soapy water If dirt is not easily removed wash with a solution of detergent in luke warm water Dry well in shade after washing and reinstall the filters back in place Plasma Filter The plasma filters behind the air filter should be checked and cleaned once in every 3 months or more ofte...

Page 23: ... not good for the health and wastes electricity Keep blinds or curtains closed Do not let direct sunshine enter the room when the air conditioner is in operation Keep the room temperature uniform Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room Make sure that the doors and windows are shut thight Avoid opening doors and windows as much as possible to...

Page 24: ...ircuit Breaker will trip Make sure there are no curtains blinds or furniture blocking the front of the air conditioner Clean the filter at least every 2 weeks See the Maintenance and Service section When the air conditioner is first turned on you need to allow time for the room to cool down Check for open furnace floor registers and cold air returns Make sure they are correct Check and remove such...

Page 25: ...P No MFL42262807 Printed in Korea ...