Operation
■
CT1 control
• If the operating current reaches I1, the operating frequency of the compressor decrease.
• After decreasing the operating frequency by 1step, if operating current is below I1 for 60 seconds continuous-
ly, the operating frequency of compressor increase by 1step.
■
CT2 control
• If the operating current of the appliance reaches I2, the compressor stop instantly and 2 minutes later the
compressor restart again.
• If CT2 occurs 5 times within 1hour, the appliance turn off and display ERROR CODE 22.
❇
I1:Current of operating frequency down
I2: Current of compressor cut off
cf. I1 is set the lowest level between intial value and in case dectection of dc paeak current.
Control table
Protection from total current control
AS-W2463RH2
13.5
13.5
14
14
15.5
AS-W2463MH2
13.5
13.5
14
14
15.5
I1
Cooling
Heating
Cooling
Heating
Outdoor temp
≥
38°C
Outdoor temp < 38°C
I2
Model
1. Chaos swing mode
• By the Chaos swing key input, the upper/lower vane automatically operates with the Chaos swing or it is
fixed to the desired direction.
CLOSED
Chaos Swing On
Chaos Swing
The first path
Mode 9
Mode 8
Mode 7
Mode 6
Mode 5
Mode 4
Mode 3
Mode 2
Mode 1
OPEN
Swing mode