Summary of Contents for AS-C30_Series

Page 1: ...his owner s manual for future reference after reading it thoroughly Prior to installation this air conditioning unit must be submitted for approval by the utility service which provides electricity EN 61000 2 EN 61000 3 Norm MODEL LS H30_Series LS H36_Series AS H30_Series AS H36_Series AS C30_Series AS C36_Series S30_Series S36_Series ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH GREEK ...

Page 2: ...of Troubleshooting Tips first you may not need to call for service at all PRECAUTION Contact the authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to ensure that they do not play with the air conditi...

Page 3: ... properly Do not damage or use an unspecified power cord Otherwise it will cause electric shock or fire due to heat generation or electric shock It will cause electric shock or fire In the supply cord is damaged it mut be replaced by the manufacturer or its service agent or a similarly quallfied person in order to avoid a hazard Y Attachment Do not modify power cord length or share the outlet with...

Page 4: ...n It may cause fire and electric shock accident It may cause electric shock Do not use the power cord close to the heating tools Do not use the power cord near flammable gas or combustibles such as gasoline benzene thinner etc It may cause fire and electric shock It may cause an explosion or fire Ventilate before operating air conditioner when gas goes out Do not disassemble or modify products ran...

Page 5: ... the head of the power plug when taking it out Operation with windows opened may cause wetting of indoor and soaking of household furniture It may cause electric shock and damage Turn off the main power switch when not using it for a long time Do not place obstacles around the absorption inlet or instead of blowing out inlet It may cause failure of product or fire It may cause failure of appliance...

Page 6: ...reserving precision devices food pets plants and art objects Such usage could damage the items 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock 3 When cleaning the unit first make sure that the p...

Page 7: ...l Receptor Receives the signals from the remote control Signal receiving sound two short beeps or one long beep Operation Indication Lamps On Off Lights up during the system operation Timer or Sleep Mode Lights up during Timer operation or Sleep mode Defrost Mode Lights up during Defrost Mode or Hot Start operation Heat pump model only Lights up during outdoor unit operation Cooling model only Pla...

Page 8: ...NG BUTTON Used to stop or start louver movement and set the desired up down airflow direction 7 ON OFF TIMER BUTTONS Used to set the time of starting and stopping operation See page 17 8 TIME SETTING BUTTONS Used to adjust the time See page 17 9 TIMER SET CANCEL BUTTON Used to set the timer when the desired time is obtained and to cancel the Timer operation See page 17 10 SLEEP MODE AUTO BUTTON Us...

Page 9: ...e the door on the remote control Set the temperature lower than the room temperature The temperature can be set within a range of 18 C 30 C in 1 C increments Set the fan speed again with the door of the remote control still closed You can select the fan speed in four steps low medium high and CHAOS Each time the button is pressed the fan speed mode is shifted 1 2 3 4 Natural wind by the CHAOS logi...

Page 10: ... change the set temperature press the Room Temperature Setting buttons The cooler or warmer you feel the more times up to two times you should press the button The set temperature will be changed automatically During Auto Operation You cannot switch the indoor fan speed It has already been set by the Fuzzy rule If the system is not operating as desired manually switch to another mode The system wi...

Page 11: ...The air conditioner changes the operation mode automatically to keep indoor temperature When room temperature vary over 2 C with respect to setting temperature air conditioner keeps the room temperature in 2 C with respect to setting temperature by auto changeover mode 1 2 Close the door on the remote control Set the temperature lower than the room temperature The temperature can be set within a r...

Page 12: ...t room temp In this case however the setting temp is not displayed in the remote control and you are not able to control the room temp either During the healthy dehumidification function the airflow volume is automatically set according to the optimization algorithm responding to the current room temp status which makes the room condition healthy and comfortable even in the high humidity season 1 ...

Page 13: ...on the remote control Set the temperature higher than the room temperature The temperature can be set within a range of 16 C 30 C in 1 C increments Set the fan speed again with the door of the remote control still closed You can select the fan speed in four steps low medium high and CHAOS Each time the button is pressed the fan speed mode is shifted Heating Operation Heat pump model only 1 2 3 4 N...

Page 14: ...to the normal cooling mode from the JET COOL mode you just press either the operation mode selection button airflow volume selection or temp setting button or the JET COOL button again NOTICE Press the Start Stop button The unit will respond with a beep Press the Jet Cool button to operate the speed cooling mode and the unit will operate in super high fan speed on cooling mode for 30 minutes To ca...

Page 15: ...Set the fan speed again with door of the remote control closed You can select the fan speed in four steps low medium high or CHAOS Each time the button is pressed the fan speed mode is shifted Air purifying operation PLASMA can be with cooling Heating or any other operations PLASMA Air Purifying Operation only If you press the only PLASMA button only PLASMA air purifying operates Then fan speed is...

Page 16: ...d 2 Auto Clean function works before and after cooling or dehumidification mode For details refer to the below points 3 When the unit is started after the reservation of Auto Clean the Cool Start function operates and indoor Fan is started after 20 seconds 4 When you press Start Stop button to turn off the unit after the you have reserved Auto Clean function the air conditioner circulates the indo...

Page 17: ...s and by 2 C in 1 hour for comfortable sleeping NOTICE Setting the Time Time can be set only when you have pressed the Reset button If you have just replaced the batteries the Reset button should be pressed to reset the time 1 Press the Start Stop button 2 Press 2nd F button and check if 2nd F icon is on 3 Press the Time Setting buttons until the desired time is set 4 Press the Timer SET button Ch...

Page 18: ... the horizontal airflow direction is changed automatically based on the CHAOS algorithm to distribute the air in the room evenly and at the same time to make the human body feel most comfortable as if enjoying a natural breeze Always use the remote control to adjust the up down airflow direction Manually moving the vertical airflow direction louver by hand could damage the air conditioner When the...

Page 19: ...erating conditions If you want to use this operation press the Auto Restart Button Heat pump Model Cooling Model Room Temp 24 C 21 C Room Temp 24 C Room Temp 21 C Operating mode Cooling Cooling Healthy Dehumidification Heating Indoor FAN Speed High High Healthy Dehumidification Rule High Setting Temperature 22 C 22 C 23 C 24 C Helpful information Fan speed and cooling capacity The cooling capacity...

Page 20: ... remove the filter 2 Clean the filter with a vacuum or warm soapy water If dirt is conspicuous wash with a solution of detergent in lukewarm water If hot water 40 C or more is used it may be deformed 3 After washing with water dry well in the shade 4 Re install the air filter NOTICE Vertical louver Horizontal louver Air filters behind front panel Air outlet vent Air inlet vent Gasoline Powder 36K ...

Page 21: ...will reduce the operating efficiency of the system and cause higher operating costs NOTICE Replacement of Purifying Filter Option Recomended use period About 2 years 1 Open front panel and remove air filters 4 Reinsert air filters and close front panel 2 Remove air purifying filters 3 Insert new air purifying filters 3 2 Air filter Side Rear Air intake vents Air outlet vents Piping Side Rear Air o...

Page 22: ...for cleaning filters 2 Check that the air inlet and outlet of the indoor outdoor unit are not blocked Do not overcool the room This is not good for your health and wastes electricity Keep blinds or curtains closed Do not let direct sunshine enter the room when the air conditioner is in operation Keep the room temperature uniform Adjust the vertical and horizontal airflow direction to ensure a unif...

Page 23: ... damp smell exuded by the walls carpet furniture or cloth items in the room Condensation occurs when the airflow from the air conditioner cools the warm room air This is the protector of the mechanism Wait about three minutes and operation will begin Is the air filter dirty See air filter cleaning instructions Has the temperature been set incorrectly Are the indoor unit s air inlet or outlet vents...