Service Manual 41
7. Cooling or Heating Mode with Sleep Mode Auto Control
• When selecting the Cooling(
) or the Heating( ) combined with the Sleep Mode Auto Control( ), the
operation diagram is as following.
■
Cooling Mode with the Sleep Mode
• The setting temperature will be automatically raised by 2°F 30 minutes later and by 4°F 1 hour later.
• The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
■
Heating Mode with the Sleep Mode(only Heating Model)
• The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
INTAKE AIR TEMP.
SETTING TEMP. +1°F
(Compressor ON)
SETTING TEMP. -1°F
(Compressor OFF)
30 minutes
30 minutes
More than
3 minutes
2°F
2°F
More than
3 minutes
COMPRESSOR
ON
OFF
ON
OFF
ON
INDOOR FAN SPEED
Low
Low
Low
Low
Low
SETTING TEMP. +6°F
(Compressor OFF)
SETTING TEMP.
(Compressor ON)
COMPRESSOR
ON
OFF
ON
OFF
ON
OFF
INDOOR FAN SPEED
Med
Low or OFF
Med
Low or OFF
Med
Low or OFF
INTAKE AIR TEMP.
More than
3 minutes
More than
3 minutes
More than
3 minutes
Operation