background image

Date:

Job

 

Name/Location:

PO

 

No.:

Architect:

Engr:

GC:

Rep:

For:

File

Approval

Mech:

Resubmit

Other

Tag

 

#:

(Company)

(Project

 

Manager)

Art

 

Cool™

 

Gallery

 

Single

 

Zone

 

Inverter

Performance:

Capacity

 

(Btu/h)

11,200

SEER

16

EER

12.0

Cooling:

LA120HVP

Heating:

Capacity

 

(Btu/h)

13,300

HSPF

8.2

Electrical:

Cooling

 

Nominal

 

Test

 

Conditions:

Heating

 

Nominal

 

Test

 

Conditions:

Indoor:

80°F

 

DB/67°F

 

WB

Indoor:

70°F

 

DB/60°F

 

WB

Outdoor: 95°F

 

DB/75°F

 

WB

Outdoor: 47°F

 

DB/43°F

 

WB

MCA

 

(A)

10

MOP

 

(A)

15

Rated

 

Amps

 

(A)

8.1

Compressor

 

(A)

7.6

Fan

 

Motor

 

(A)

0.25

Piping:

Liquid

 

Line

 

(in,

 

OD)

1/4

Vapor

 

Line

 

(in,

 

OD)

3/8

Additional

 

Refrigerant

 

(oz/ft)

0.22

Max

 

Elevation

 

(ft)

33

Controls

 

Features:

 

•24-Hour

 

on/o

ff 

mer

 

•Auto

 

changeover

 

•Auto

 

restart

 

•Auto

 

sleep

 

mode

 

•Built-in

 

low

 

ambient

 

standard

 

down

 

to

 

14°F

 

(cooling

 

mode)

 

•Chaos

 

Wind

 

•Customizable

 

art

 

panel

 

 

•Dehumidifying

 

mode

 

•Fan

 

mode

 

•Jet

 

Cool/Jet

 

Heat

 

•Self-cleaning

 

indoor

 

coil

 

•Three-way

 

cooling

Operating

 

Range:

Cooling

 

(°F

 

DB)

14-118

Heating

 

(°F

 

WB)

14-75

Outdoor

 

Unit:

Indoor

 

Unit:

Cooling

 

(°F

 

DB)

64-90

Heating

 

(°F

 

DB)

60-86

Unit

 

Data:

ODU

 

Net

 

Weight

 

(lbs)

78

ODU

 

Shipping

 

Weight

 

(lbs)

82

IDU

 

Net

 

Weight

 

(lbs)

31

IDU

 

Shipping

 

Weight

 

(lbs)

34

Refrigerant

 

Type

R410A

Refrigerant

 

Charge

 

(lbs)

2.21

Fan:

Standard

 

Features:

 

•Limited

 

Seven

 

Year

 

Compressor

 

Warranty

 

•Limited

 

Five

 

Year

 

Func onal

 

Parts

 

Warranty

Notes:

 

1.Acceptable

 

opera ng

 

voltage:

 

187V-253V.

 

2.Piping

 

lengths

 

are

 

equivalent.

 

3.Sound

 

Pressure

 

levels

 

are

 

tested

 

in

 

an

 

anechoic

 

chamber

 

under

 

ISO

 

Standard

 

1996.

 

4.All

 

communica on

 

cable

 

to

 

be

 

minimum

 

18

 

AWG,

 

2-conductor,

 

stranded,

 

shielded

 

and

 

must

 

comply

 

with

 

applicable

 

local

 

and

 

national

 

code.

 

5.See

 

Engineering

 

Manual

 

for

 

sensible

 

and

 

latent

 

capaci es.

 

6.Power

 

wiring

 

cable

 

size

 

must

 

comply

 

with

 

the

 

applicable

 

local

 

and

 

na onal

 

code.

 

7.The

 

indoor

 

unit

 

comes

 

with

 

a

 

dry

 

helium

 

charge.

 

8.This

 

data

 

is

 

rated

 

0

   

above

 

sea

 

level,

 

with

 

24.6

   

of

 

refrigerant

 

line

 

and

 

a

 

0

   

level

 

difference

 

between

 

outdoor

 

and

 

indoor

 

units.

  

 

9.Must

 

follow

 

installa on

 

instruc ons

 

in

 

the

 

applicable

 

LG

 

installa on

 

manual.

ODU

 

Type

Propeller

IDU

 

Type

Turbo

Motor/Drive

Brushless

 

Digitally

 

Controlled/Direct

ODU

 

Max

 

Air

 

Flow

 

Rate

 

(CFM)

1,165

IDU

 

Max

 

Air

 

Flow

 

H/M/L

 

(CFM)

350/300/229

Dehumidification

 

(pts/hr)

3.17

Page

 

1

 

of

 

2

VRF-SB-AK-002-US

 

012M17

For

 

continual

 

product

 

development,

 

LG

 

reserves

 

the

 

right

 

to

 

change

 

specifications

 

without

 

notice.

LG

 

Electronics

 

U.S.A.,

 

Inc.,

 

Englewood

 

Cliffs,

 

NJ.

 

All

 

rights

 

reserved.

 

“LG

 

Life’s

 

Good”

 

is

 

a

 

registered

 

trademark

 

of

 

LG

 

Corp.

 

/www.lghvac.com

Outdoor

 

Unit:

Indoor

 

Unit:

Cooling

 

Power

 

Input

 

(kW)

0.93

Heating

 

Power

 

Input

 

(kW)

1.25

Refrigerant

 

Control

EEV

Heat

 

Exchanger

 

Coating

GoldFin™

Power

 

Supply

 

(V¹/Hz/Ø)

208-230/60/1

Power

 

Supply

 

(V¹/Hz/Ø)

208-230/60/1

Max

 

Pipe

 

Length

 

(ft)²

49

ODU

 

Sound

 

Pressure

 

Max

 

±3

 

dB(A)³

45

Indoor

 

Sound

 

Pressure

 

(H/M/L)

 

±3

 

dB(A)³

42/36/32

Communication

 

Cable

 

(No

 

x

 

AWG)

4

 

x

 

18

Outdoor

 

Unit

 

(ODU)

 

-

 

LAU120HVP Indoor

 

Unit

 

(IDU)

 

-

 

LAN120HVP

SEER

 

-

 

Seasonal

 

Energy

 

Efficiency

 

Ratio EER

 

-

 

Energy

 

Efficiency

 

Ratio

HSPF

 

-

 

Heating

 

Seasonal

 

Performance

 

Factor

MOP

 

-

 

Maximum

 

Overcurrent

 

Protection MCA

 

-

 

Minimum

 

Circuit

 

Ampacity

Optional

 

Accessories:

7-Day

 

Programmable

 

Controller

 

(Black)

 

-

 

PQRCVSL0

7-Day

 

Programmable

 

Controller

 

(White)

 

-

 

PQRCVSL0QW

Simple

 

Controller

 

with

 

Mode

 

(Black)

 

-

 

PQRCVCL0Q

Dry

 

Contact

 

for

 

Third

 

Party

 

Thermostat

 

-

 

PQDSBNGCM1

Fan

 

Speeds

 

(Fan/Cooling/Heating)

4/5/5

Quanity

 

(ODU

 

+

 

IDU)

(1

 

+

 

1)

Reviews: