background image

Date:

Job

 

Name/Location:

PO

 

No.:

Architect:

Engr:

GC:

Rep:

For:

File

Approval

Mech:

Resubmit

Other

(Company)

(Project

 

Manager)

Tag

 

#:

ARNU093CEA2

Multi

 

V™

 

Floor

 

Standing

 

(with

 

case)

Btu/h

 

Indoor

 

Unit

Performance:

Cooling

 

Nominal

 

Test

 

Conditions:

Heating

 

Nominal

 

Test

 

Conditions:

Indoor:

80°F

 

DB/67°F

 

WB

Outdoor
:

95°F

 

DB

Indoor:

70°F

 

DB

Outdoor
:

47°F

 

DB/43°F

 

WB

Heating

 

Capacity

 

(Btu/h)

 

10,900

Electrical:

Power

 

Supply

 

(V/Hz/Ø)

208

230/60/1

Rated

 

Amps

 

(A)

 

0.1

Piping:

Refrigerant:

Condensate:

Standard

 

Features:

 

•Limited

 

Warranty

 

with

 

LG

 

Cer

fi

ed

 

Installa on

     

•Two

 

Year

 

Functional

 

Parts

 

Warranty

Controls

 

Features:

 

•Auto

 

changeover

 

  

(Heat

 

Recovery

 

only)

 

•Auto

 

opera on

 

•Auto

 

restart

 

•Child

 

lock

 

•Dual

 

thermistor

 

control

 

•Group

 

control

 

•E.S.P.

 

control

 

•Hot

 

start

 

•Self

 

diagnos cs

 

•Sleep

 

mode

 

•Timer

 

(on/o

)

 

•Weekly

 

schedule

 

•So

 

dry

 

(dehumidi

fi

ca on)

 

•Fan

 

speed

 

control

Unit

 

Data:

Refrigerant

 

Type

R410A

Refrigerant

 

Control

EEV

Fan:

Type

Sirocco

Quantity

1

Motor/Drive

Brushless

 

Digitally

 

Controlled/Direct

Notes:

Power

 

Input²

 

(W)

30

Airflow

 

Rate

 

H/M/L

 

(CFM)

335/300/265

Total

 

Cooling

 

Capacity¹

 

(Btu/h)

9,600

Filter

Washable

 

Pre

filter

 

1.See

 

Engineering

 

Manual

 

for

 

sensible

 

and

 

latent

 

capaci es.

 

2.The

 

Power

 

Input

 

is

 

rated

 

at

 

high

 

speed.

 

3.Requires

 

a

 

7

Day

 

programmable

 

controller.

 

4.Sound

 

Pressure

 

levels

 

are

 

tested

 

in

 

an

 

anechoic

 

chamber

 

under

 

ISO

 

Standard

 

1996.

 

5.All

 

communica on

 

cable

 

to

 

be

 

minimum

 

18

 

AWG,

 

2

conductor,

 

stranded,

 

shielded

 

and

 

must

 

comply

 

with

 

applicable

 

local

 

and

 

national

 

code.

 

6.Power

 

wiring

 

cable

 

size

 

must

 

comply

 

with

 

the

 

applicable

 

local

 

and

 

na onal

 

code.

 

7.This

 

unit

 

comes

 

with

 

a

 

dry

 

nitrogen

 

charge.

 

8.This

 

data

 

is

 

rated

 

0

   

above

 

sea

 

level,

 

with

 

25

   

of

 

refrigerant

 

line

 

per

 

indoor

 

unit

 

and

 

a

 

0

   

level

 

difference

 

between

 

outdoor

 

and

 

indoor

 

units.

  

All

 

capacities

 

are

 

net

 

with

 

a

 

combination

 

ratio

 

between

 

95

 

 

105%.

 

9.Must

 

follow

 

installa on

 

instruc ons

 

in

 

the

 

applicable

 

LG

 

installa on

 

manual.

9,600

Optional

 

Accessories:

Condensate

 

Line

 

(in,

 

OD)

1/2

Factory

 

Installed

 

Pump

No

Sound

 

Pressure

⁴ 

dB(A)

 

(H/M/L)

36/34/32

Net

 

Unit

 

Weight

 

(lbs)

60

Shipping

 

Weight

 

(lbs)

69

Liquid

 

Line

 

(in,

 

OD)

1/4

 

Flare

Vapor

 

Line

 

(in,

 

OD)

1/2

 

Flare

Page

 

1

 

of

 

2

VRF

SB

DL

002

US

 

012C22

For

 

continual

 

product

 

development,

 

LG

 

reserves

 

the

 

right

 

to

 

change

 

specifications

 

without

 

notice.

LG

 

Electronics

 

U.S.A.,

 

Inc.,

 

Englewood

 

Cliffs,

 

NJ.

 

All

 

rights

 

reserved.

 

“LG

 

Life’s

 

Good”

 

is

 

a

 

registered

 

trademark

 

of

 

LG

 

Corp.

 

/www.lg

vrf.com

Wireless

 

Handheld

 

Remote

 

Controller

   ‐ 

PQWRHDF0

7

Day

 

Programmable

 

Controller

 

(Black)

 ‐ 

PQRCVSL0

Simple

 

Controller

 

with

 

Mode

 

(Black)

 ‐ 

PQRCVCL0Q

Simple

 

Controller

 

without

 

Mode

 

(Black)

 

PQRCHCA0Q

Dry

 

Contact

 

Unit

 ‐ 

PQDSB1

Wall

 

Mounted

 

Temperature

 

Sensor

 ‐ 

PQRSTA0

7

Day

 

Programmable

 

Controller

 

(White)

 ‐ 

PQRCVSL0QW

Simple

 

Controller

 

with

 

Mode

 

(White)

 ‐ 

PQRCVCL0QW

Simple

 

Controller

 

without

 

Mode

 

(White)

 ‐ 

PQRCHCA0QW

Dry

 

Contact

 

Unit

 ‐ 

PQDSBC

³

Reviews: