Summary of Contents for APNW48GTA0

Page 1: ... MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference P NO MFL67724502 www lg com TYPE FLOOR STANDING MODEL APNW48GTA0 APUW48GTA0 ENGLISH TÜRKÇE ...

Page 2: ...irection of the air flow vertically or horizontally to circulate indoor air Speed up the fan to cool or warm indoor air quickly in a short period of time Open windows regularly for ventilation as the indoor air quality may deteriorate if the air con ditioner is used for many hours Clean the air filter once every 2 weeks Dust and impurities collected in the air filter may block the air flow or weak...

Page 3: ...lectrician or an Authorized Service Center Do not disassemble or repair the product There is risk of fire or electric shock Always ground the product There is risk of fire or electric shock Install the panel and the cover of control box securely There is risk of fire or electric shock Always install a dedicated circuit and breaker Improper wiring or installation may cause fire or electric shock Us...

Page 4: ...hurricane arrives There is risk of property damage failure of product or electric shock Do not open the inlet grill of the product during operation Do not touch the electrostatic filter if the unit is so equipped There is risk of physical injury electric shock or product failure When the product is soaked flooded or submerged contact an Authorized Service Center There is risk of fire or electric s...

Page 5: ... personal injury and fail ure of product Always insert the filter securely Clean the filter every two weeks or more often if necessary A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage Do not insert hands or other objects through the air inlet or outlet while the product is in operation There are sharp and moving parts that could cause perso...

Page 6: ...l preparation 12 OPERATING INSTRUC TIONS 12 Cooling Mode 12 Heating Mode 12 Airflow Setting 12 Fan Speed Mode 13 Dehumidification Mode 13 Power Cooling Heating Mode 13 Blowing Mode 13 Simple Reservation 14 Defrost Mode 14 Child Lock Operation Function 14 Auto Re Operation Function 15 MAINTENANCE AND SERVICE 15 Indoor Unit 16 When the air conditioner is not going to be used for a long time 16 Opera...

Page 7: ...ing precision de vices food pets plants and art objects Such usage could damage the items Cleaning and maintenance Do not touch the metal parts of the unit when removing the filter Injuries can occur when han dling sharp metal edges Do not use water to clean inside the air conditioner Exposure to water can destroy the insula tion leading to possible electric shock When cleaning the unit first make...

Page 8: ...Control Louver 3 Display Control Panel 4 Filter 5 Air Inlet 6 Control Box Outdoor unit 1 Air Outlet 2 Air Inlet rear side 3 Bottom plate 4 Refrigerant Pipe Port Bottom plate is made of material that have corrosion endurance and is not painted in order to save environment 1 4 2 3 6 5 2 1 3 4 PRODUCT INTRODUCTION ...

Page 9: ...ating operation lamp 8 Outdoor unit operation Preheating Defrost Timer Child lock lamp 9 Room temp Set temp display ON OFF timer display 10 Indoor fan speed lamp 11 Up Down air flow lamp 12 Left Right air flow lamp 13 Start Stop button 14 Operation mode selection button 15 Power cooling heating mode button 16 Room temperature setting button 17 Indoor fan speed button 18 Air flow direction button 1...

Page 10: ... operation lamp 2 Power ON OFF button Operation will start when this button is pressed and stop when the button is pressed again 3 Indoor fan speed button To select the desired fan speed 4 Temperature setting button 5 A Cooling button 6 B Heating button 7 D Dehumidification button Can effectively remove humidity when at the time of rainy season or high humidity 8 C Auto operation button Auto heati...

Page 11: ...es are different from standard dry cells in shape dimensions and performance Change the batteries with a new one if the remote control does not work properly after using for an extended period of time CAUTION When not using remote controller for a long time flowing of dry cell liquid may cause the failure of product therefore remove all dry cells When replacing dry cell AAA replace two of them all...

Page 12: ...Control 1 Press button to turn on the indoor 2 Press button and the louvers will swing left and right 3 Press button again to set the vertical louver at the desired airflow direction Airflow Setting Table Fan Speed Mode 1 Press button to turn on the indoor 2 Press button to select fan speed You can select the fan speed in four steps low mid high super high Each time the button is pressed the fan s...

Page 13: ...ir When canceling operation press button once more During fan mode outdoor fan and com pressor will not be operated Auto Operation Mode 1 Press button to turn on the indoor 2 Press 2 button to select Auto Operation Mode 3 Adjust the desired temperature by press ing buttons When room temperature is higher than desired temperature cooling operation will be performed and when it is lower heating oper...

Page 14: ...nction When power is supplied again after unit oper ation has been stopped because of interrup tion of power supply due to outage or other causes auto re operation will be performed by remembering previous setting When power is supplied outdoor unit opera tion will be started within 3 minutes 1 Auto re operation function can be estab lished released by manipulating indoor unit button When initial ...

Page 15: ...mage the surfaces of the air condi tioner Filter Cleaning Please clean it once in a week 1 Remove the Air filters Take hold of the tab and pull slightly for ward to remove the filter 2 Clean dirt from the air filter using a vacuum cleaner or washing with water If dirt is conspicuous wash with a neutral detergent in lukewarm water If hot water 50 C or more is used it may be deformed 3 After washing...

Page 16: ... idea to open them and ventilate the room now and then When the air conditioner is not going to be used for a long time When air conditioner is not going to be used for a long time 1 Operate the air conditioner at the following settings for 2 to 3 hours Type of operation Fan operation mode This will dry out the internal mechanisms Helpful information The air filters and your electiric bill If the ...

Page 17: ... air Air conditioner does not operate for about 3 minutes when restart This is the protector of the mechanism Wait about three min utes and operation will begin Does not cool or heat effectively Is the air filter dirty See air filter cleaning instructions The room may have been very hot when the room air condi tioner was first turned on Allow time for it to cool down Has the temperature been set i...

Page 18: ...18 ENGLISH ...

Page 19: ...lgesi İk inci Kısım Gaziler Caddesi No 2 45030 Manisa İrtibat Adresi Ankara Asfaltı Üzeri Acıba dem Mah Onur Sokak No 18 A 34718 Koşuyolu Kadiköy İSTANBUL Telefonu 0216 544 11 00 Telefaksı 0216 325 80 70 ÜRETİCİ FİRMA LG Electronics Inc 76 Seongsan Gu Changwon City Gyeong Nam 642 713 R O K South Korea ...