background image

MFL67724515

Rev.03_072319

OWNER’S MANUAL

AIR

CONDITIONER

Please read this manual carefully before operating your set and retain it for future 
reference.

Floor Standing

APNQ30GR5A3, APNQ36GR5A3, APNQ36LR5A3, APNQ48GT3E3, APNQ48LT3E3,  
APNQ24GS1A4, APNQ30GR5A4, APNQ36GR5A4, APNQ48GT3E4

I.15.LEI3.02843.0717

www.lg.com

Copyright © 2016 - 2019 LG Electronics Inc. All Rights Reserved.

ENGLISH

Tiếng V

iệt

BAHASA INDONESIA

Summary of Contents for APNQ24GS1A4

Page 1: ...erating your set and retain it for future reference Floor Standing APNQ30GR5A3 APNQ36GR5A3 APNQ36LR5A3 APNQ48GT3E3 APNQ48LT3E3 APNQ24GS1A4 APNQ30GR5A4 APNQ36GR5A4 APNQ48GT3E4 I 15 LEI3 02843 0717 www lg com Copyright 2016 2019 LG Electronics Inc All Rights Reserved ENGLISH Tiếng Việt BAHASA INDONESIA ...

Page 2: ...osed tightly while you are operating the air conditioner Adjust the direction of the air flow vertically or horizontally to circulate indoor air Speed up the fan to cool indoor air quickly in a short period of time Clean the air filter once every 2 weeks Dust and impurities collected in the air filter may block the air flow or weaken the cooling dehumidifying functions For your records Staple your...

Page 3: ...nstruction concerning use of the appliance by a person responsible for their safety Installation Do not install duct through disassemble or repair the product yourself This product can not install duct Do not use a defective or underrated circuit breaker Use this appliance on a dedicated circuit There is risk of fire or electric shock For electrical work contact the dealer seller a qualified elect...

Page 4: ...failure of product Do not use the product in a tightly closed space for a long time Oxygen deficiency could occur When flammable gas leaks turn off the gas and open a window for ventilation before turn the product on Do not use the telephone or turn switches on or off There is risk of explosion or fire If strange sound smell or smoke comes from product turn the breaker off or disconnect the power ...

Page 5: ...lure Use a soft cloth to clean Do not use harsh detergents solvents etc There is risk of fire electric shock or damage to the plastic parts of the product Do not touch the metal parts of the product when removing the air filter They are very sharp There is risk of personal injury Do not step on or put anything on the product outdoor units There is risk of personal injury and failure of product Alw...

Page 6: ...10 Wireless remote controller 12 Remote control preparation 13 OPERATING INSTRUCTIONS 13 Cooling Mode 13 Airflow Setting 13 Fan Speed Setting 14 Dehumidification Mode 14 Power Cooling Mode 14 Fan Mode 14 Simple Reservation 15 Child Lock Operation Function 15 Auto Dry Function 16 Auto Restart Operation 17 MAINTENANCE AND SERVICE 17 Indoor Unit 18 Operation Tips 19 Troubleshooting Tips Save time and...

Page 7: ...rving precision devices food pets plants and art objects Such usage could damage the items Cleaning and maintenance Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock When cleaning the unit first make ...

Page 8: ...NTRODUCTION ENGLISH Name of parts Indoor unit 1 Left Right Airflow Control Louver 2 Up Down Airflow Control Louver 3 Display Panel 4 Air filter 5 Air Inlet 6 Control Box 1 4 2 3 6 5 1 2 3 5 4 PRODUCT INTRODUCTION ...

Page 9: ...N OFF button 8 Operation mode selection button 9 Room temperature setting button 10 Indoor fan speed button 11 Signal receptor 1 Room temp Set temp display 2 Auto operation lamp 3 Fan mode operation lamp 4 ON OFF button 5 Operation mode selection button 6 Room temperature setting button 7 Indoor fan speed button 8 Outdoor Operation lamp 9 Reservation lamp 10 Indoor fan speed lamp 11 Power cool lam...

Page 10: ... Control panel Description Remote control operation lamp Power ON OFF button Operation will start when this button is pressed and stop when the button is pressed again Indoor fan speed button To select the desired fan speed Temperature setting button A Cooling button Auto dry button If setting this function evaporator will be automatically dried before turning off the air conditioner D Dehumidific...

Page 11: ...d to direct sunlight or next to a heating unit or other heat source Control panel Description Power ON OFF button Operation will start when this button is pressed and stop when the button is pressed again Temperature setting button Indoor fan speed button To select the desired fan speed Cooling button Fan mode button Air flow direction button Up down Adjust air flow direction vertically Air flow d...

Page 12: ...erent from standard dry cells in shape dimensions and performance Change the batteries with a new one if the remote control does not work properly after using for an extended period of time CAUTION When not using remote controller for a long time flowing of dry cell liquid may cause the failure of product therefore remove all dry cells When replacing dry cell AAA replace two of them all with new o...

Page 13: ... louver at the desired airflow direction Left Right Airflow Direction Control 1 Press button to turn on the indoor 2 Press J button and the louvers will swing left and right 3 Press J button again to set the vertical louver at the desired airflow direction Fan Speed Setting 1 Press button to turn on the indoor 2 Press button to select fan speed You can select the fan speed in four steps Low Med Hi...

Page 14: ...he indoor unit 2 Press button to circulate indoor air When canceling operation press button once more During fan mode outdoor fan and compressor will not be operated During fan mode indoor unit turns on the fan mode lamp room temperature lamp and fan speed lamp of its display panel Simple Reservation This function is able to turn on unit after a setting time 1 When the unit is turned off adjust de...

Page 15: ...on after setting the function evaporator in indoor unit will be automatically dried as showing counting 00 to 99 on its display panel 3 After indicating 99 on the display panel the unit will be automatically turned off Auto dry function is released at initial state as standard If manipulating indoor unit press the button and button simultaneously for 3 seconds If manipulating remote control for Co...

Page 16: ...l be started within 3 minutes 1 Auto Restart Operation can be established released by manipulating indoor unit button When initial state Auto Restart Operation will be set up as standard Press the 4 buttons simultaneously for 3 seconds The unit will respond with beep and Restart Operation will be removed After function release Press the 4 buttons simultaneously for 3 seconds The unit will respond ...

Page 17: ... surfaces of the air conditioner Filter Cleaning Please clean it once in a week 1 Remove the Air filters Take hold of the tab and pull slightly forward to remove the filter 2 Clean dirt from the air filter using a vacuum cleaner or washing with water If dirt is conspicuous wash with a neutral detergent in lukewarm water If hot water 40 C or more is used it may be deformed 3 After washing with wate...

Page 18: ...dows are kept closed it is a good idea to open them and ventilate the room now and then When air conditioner is not going to be used for a long time 1 Operate the air conditioner at the following settings for 2 to 3 hours Type of operation Fan operation mode This will dry out the internal mechanisms Helpful information The air filters and your electric bill If the air filters become clogged with d...

Page 19: ...protector of the mechanism Wait about three minutes and operation will begin Does not cool effectively Is the air filter dirty See air filter cleaning instructions The room may have been very hot when the room air conditioner was first turned on Allow time for it to cool down Has the temperature been set incorrectly Are the indoor unit s air inlet or outlet vents obstructed The air conditioner ope...

Page 20: ...20 ENGLISH ...

Page 21: ...Diimpor oleh PT LG ELECTRONICS INDONESIA GANDARIA 8 OFFICE TOWER LT 29 BC 31 ABCD JL SULTAN ISKANDAR MUDA KEBAYORAN LAMA JAKATA SELATAN 12240 DKI JAKARTA RAYA INDONESIA ...