1) No Cooling operation performed
: The unit does not operate.
Possible Trouble 1
YES
YES
YES
NO
YES
Is the input voltage
of transformer AC220V?
Is the input voltage
of IC01D DC14V?
Check the FUSE
and the wiring diagram.
Is the output voltage
of IC01D DC12V?
Is the PIN 55,64 of
MICOM. DC5V?
Exchange MICOM
YES
NO
Check the main P.C.B
pattern
NO
NO
Check the D02D~D05D
NO
YES
Exchange
the transformer
Is shorted the
transformer output?
NO
YES
Is the output voltage
of IC03D DC5V?
NO
Exchange IC01D
Exchange IC03D
Is the output voltage
of transformer about AC14V?
Check the
5V P.C.B pattern.
Possible Trouble 2
: The indoor fan does not operate.
NO
Is IC03M operated
normally?
Check the fan motor
and connector.
(CN-MOTOR)
YES
Is the each Relay
any problem?
NO
YES
Exchange IC03M
Exchange Relay
Electronic Parts Troubleshooting Guide