![LG ANUQ54GS0 Installation Manual Download Page 9](http://html.mh-extra.com/html/lg/anuq54gs0/anuq54gs0_installation-manual_206640009.webp)
WIRING CONNECTION
9
ENGLISH
Electrical Wiring
Perform the electrical wiring work according
to the electrical wiring connection.
- All wiring must comply with local require-
ments.
- Select a power source that is capable of sup-
plying the current required by the air condi-
tioner.
- Use a recognized ELCB(Electric Leakage
Circuit Breaker) between the power source
and the unit. A disconnection device to ade-
quately disconnect all supply lines must be
fitted.
- Model of circuit breaker recommended by
authorized personnel only
Outdoor
Indoor
Main
power source
Switch box
ELCB
Model
Phase(ø) ELCB
AUUQ54GHT0
ANUQ54GS0
1
40A
WIRING CONNECTION
Connecting Cables between Indoor Unit and Outdoor Unit
Outdoor
unit
Indoor
unit
1
2
3
1
2
3