Installation plate
B
ar
Copper pipe
Clamp handle
Red arrow mark
Cone
Yoke
Handle
B
ar
"A"
Inclined
Inside is shiny without scratches
Smooth all round
Even length
all round
Surface
damaged
Cracked Uneven
thickness
= Improper flaring =
INSTALLATION
10
ENGLISH
Check
1
Compare the flared work with the figure
by.
2
If a flared section is defective, cut it off
and do flaring work again.
Installation of Indoor Unit
1
Hook the indoor unit onto the upper por-
tion of the installation plate.( engage the
three hooks at the top of the indoor unit
with the upper edge of the installation
plate) Ensure that the hooks are properly
seated on the installation plate by moving
it left and right
2
Unlock the tubing holder from the chassis
and mount between the chassis and instal-
lation plate in order to separate the bottom
side of the indoor unit from the wall.
* The feature can be changed according a
type of model.
Connecting the Piping
1
Pull the screw cap at the bottom of the in-
door unit
2
Remove the chassis cover from the unit by
loosing 3 screws (Be careful not to scratch
Horizontal Vane Main!)
Chassis cover
Tubing Holder