background image

P/NO : MFL67737207

www.lg.com

INSTALLATION MANUAL

AIR CONDITIONER 

• Please read this installation manual completely before installing the product.
• Installation work must be performed in accordance with the national wiring 
  standards by authorized personnel only.
• Please retain this installation manual for future reference after reading it 
  thoroughly.

TYPE : WALL MOUNTED

*MFL67737207*

ENGLISH

TÜRK

ÇE

Summary of Contents for AMNW24GDCR0

Page 1: ... manual completely before installing the product Installation work must be performed in accordance with the national wiring standards by authorized personnel only Please retain this installation manual for future reference after reading it thoroughly TYPE WALL MOUNTED MFL67737207 ENGLISH TÜRKÇE ...

Page 2: ...condi tioner is used for many hours Clean the air filter once every 2 weeks Dust and impurities collected in the air filter may block the air flow or weaken the cooling dehumidifying functions For your records Staple your receipt to this page in case you need it to prove the date of purchase or for warranty purposes Write the model number and the serial number here Model number Serial number You c...

Page 3: ... use a power cord a plug or a loose socket which is damaged Otherwise it may cause a fire or electrical shock For electrical work contact the dealer seller a qualified electrician or an Authorized Service Center Do not disassemble or repair the product There is risk of fire or electric shock Always ground the product There is risk of fire or electric shock Install the panel and the cover of contro...

Page 4: ...kage Keep level even when installing the product To avoid vibration or water leakage Do not install the product where the noise or hot air from the outdoor unit could damage the neigh borhoods It may cause a problem for your neighbors Use two or more people to lift and transport the product Avoid personal injury Do not install the product where it will be exposed to sea wind salt spray directly It...

Page 5: ...ing the Piping 10 Good case 11 Bad case 11 Installation of Indoor Unit 11 Left side piping 12 Right side piping 12 Connecting the installation pipe and drain hose to the indoor unit 12 Wrap the insulation material around the connecting portion 13 Finishing the indoor unit installation 13 Connecting the Cables 13 Indoor unit 14 Checking the Drainage 14 To check the drainage 14 Drain piping 15 Insta...

Page 6: ... C screw 2 EA Remote control holder 1 EA The feature can be changed according a type of model Screws for fixing panels are attached to decoration panel Figure Figure Name Screw driver Electric drill Measuring tape Knife Hole core drill Spanner Torque wrench Multi meter Hexagonal wrench Ammeter Gas leak detector Thermometer Level Flaring tool set Name ...

Page 7: ...emove the air filters and pour water into the heat exchanger Saddle Installation plate Sleeve Bushing Sleeve Putty Gum Type Sealant Bend the pipe as closely on the wall as possible but be careful that it doesn t break NOTE You should purchase the installation parts The feature can be changed according a type of model ENGLISH ...

Page 8: ...allation plate on the wall with type A screws If mounting the unit on a concrete wall use anchor bolts Mount the installation plate horizontally by aligning the centerline using Horizontal meter 2 Measure the wall and mark the centerline It is also important to use caution concern ing the location of the installation plate Routing of the wiring to power outlets is through the walls typically Drill...

Page 9: ...cross section of pipe tube 2 While removing burrs put the end of the copper tube pipe in a downward direction while removing burrs location is also changed in order to avoid dropping burrs into the tubing Putting nut on Remove flare nuts attached to indoor and outdoor unit then put them on pipe tube having completed burr removal not possible to put them on after finishing flare work Flaring work 1...

Page 10: ... the installation plate engage the three hooks at the top of the indoor unit with the upper edge of the installation plate Ensure that the hooks are properly seated on the installation plate by moving it left and right 2 Unlock the tubing holder from the chassis and mount between the chassis and instal lation plate in order to separate the bottom side of the indoor unit from the wall The feature c...

Page 11: ...end to the left side slowly Bad case Following bending case from right to left di rectly may cause damage to the tubing The feature can be changed according a type of model Left side piping 11 INSTALLATION ENGLISH CAUTION Installation Information For right piping Follow the instruction above Tubing holder Pipe Port Indoor unit back side view Left Backwards Right Drain hose Connecting pipe Connecti...

Page 12: ... by wrapping them with vinyl tape sufficient enough to cover where they fit into the rear piping housing section mm inch kgf m Ø6 35 1 4 1 8 2 5 Ø9 52 3 8 3 4 4 2 Ø12 7 1 2 5 5 6 5 Ø15 88 5 8 6 3 8 2 Ø19 05 3 4 9 9 12 1 Wrench Indoor unit tubing Open end wrench fixed Connection pipe Flare nut Vinyl tape narrow Adhesive Drain pipe Indoor unit drain hose Connecting pipe Connecting cable Tape Drain h...

Page 13: ... by con necting the wires to the terminals on the con trol board individually according to the outdoor unit connection Ensure that the color of the wires of the outdoor unit and the terminal No are the same as those of the indoor unit 1 Insert the connecting cable through the bottom side of indoor unit and connect the cable You can see detail contents in Con necting the cables section 2 Secure the...

Page 14: ...pe model Drain piping 1 The drain hose should point downward for easy drain flow 2 Do not make drain piping like the follow ing The feature can be changed according a type of model Connecting area drain hose Leakage checking Drain pan Drain hose Leakage checking Downward slope Do not raise Water leakage Accumulated drain water Air Waving Water leakage Tip of drain hose dipped in water Water leakag...

Page 15: ...perly connected Check that the gas and liquid side service valves are fully open Prepare remote controller 1 Remove the battery cover by pulling it ac cording to the arrow direction 2 Insert new batteries making sure that the and of battery are installed correctly 3 Reattach the cover by pushing it back into position Allergy Free Filter Triple Filter Optional Plasma Filter NOTE Use 2 AAA 1 5volt b...

Page 16: ......