1. Specification
Power supply
Ø, V, Hz
Cooling capacity
kW
Btu/h
Heating capacity
kW
Btu/h
Current Nominal running current
A
Fan
Motor type
Fan type
Motor output x Number of unit
Air flow rate
CMM
(H/M/L)
l/s
Capacitor
μF/Vac
Drive
Coil
Row x column x FPI
mm
Dimensions (WxHxD) Body
mm(inch)
Weight
Body
kg(lbs)
Sound level (H/M/L)
dB(A)+3
Piping
Liquid
mm(inch)
connections
Gas
mm(inch)
Dehumidification rate
l/h
Safety devices
Temperature sensor
Referigerant
Referigerant control
Connectable outdoor unit
Power and transmission interunit cable
No. x AWG
Model
AMNW09GAF11
[LMAN097HVP]
AMNW12GAF11
[LMAN127HVP]
Indoor unit type
ART COOL
1, 208/230, 60
1, 208/230, 60
2.64
3.28
9,000
11,200
3.05
3.90
10,400
13,300
0.2
0.2
BLDC
BLDC
Turbo fan
Turbo fan
24 x 1
24 x 1
7.7/5.9/4.4
8.9/7.3/5.6
128/98/73
148/122/93
-
-
Direct Drive
Direct Drive
2R x 20C x 21
2R x 20C x 21
600 x 600 x 147(23.6 x 23.6 x 5.8) 600 x 600 x 147(23.6 x 23.6 x 5.8)
14.5(32.0)
14.5(32.0)
39 / 35 / 31
42 / 38 / 34
6.35(1/4)
6.35(1/4)
9.52(3/8)
9.52(3/8)
1.20 1.40
Fuse, Thermal Protector for Fan Motor
Thermistor
Thermistor
R410A
R410A
EEV(in Outdoor unit or BD)
EEV(in Outdoor unit or BD)
Multi F / F DX series
Multi F / F DX series
4 x 18(Including Earth)
4 x 18(Including Earth)
Conversion Formula
kW
= Btu/h
×
0.0002931
CFM = CMM
×
35.3
Note:
1. All data are based on the following conditions:
- Cooling Temperature : Indoor 26.7℃(80℉) DB / 19.4℃(67℉) WB
Outdoor 35℃(95℉) DB / 23.9℃(75℉) WB
- Heating Temperature : Indoor 21.1℃(70℉) DB / 15.6℃(60℉) WB
Outdoor 8.33℃(47℉) DB / 6.11℃(43℉) WB
- Piping Length : Interconnected Pipe Length = 7.5m
- Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero.
2. Wiring cable size must comply with the applicable local and national code.
3. Due to our policy of innovation some specifications may be changed without notification.
4. Sound Level Values are measured at Anechoic chamber.
Therefore, these values can be increased owing to ambient conditions during operation.