20 | ProduCT dATA
Art Cool Mirror W
all Mounted Engineering Manual
Due to our policy of continuous product innovation, some specifications may change without notification.
rEFrigErant FloW diagraMS
LAn090HSV2, LAu090HSV2
LAn120HSV2, LAu120HSV2
Indoor Unit
Outdoor Unit
Heat
Exchanger
(Evaporator)
Heat
Exchanger
(Condenser)
Compressor
Accumulator
Gas Side
3-Way Valve
2-Way Valve
Liquid Side
Cooling
Heating
Reversing Valve
EEV
Th1
Th5
Th2
Th6
Th3
Th4
LOC.
Description
PCB Connector
Th1
CN-TH1(Indoor)
Th2
CN-TH2 (Indoor)
Th3
CN-TH3 (Indoor)
Th4
CN-TH2 (Outdoor)
Th5
CN-TH1(Outdoor)
Th6
Indoor air temperature thermistor
Evaporator middle temperature thermistor
Discharge pipe temperature thermistor
Heat exchanger temperature thermistor
Outdoor air temperature thermistor
Water level sensor (Option)