16
Restarting the Air
Conditioner Automatically
When the air conditioner is turned on again
after a power failure, this function restores
the previous settings.
Disabling Auto Restart
1
Open the front cover (Type2) or
horizontal vane (Type1).
2
Press the
ON/OFF
button and hold it for
6 seconds, then the unit will beep twice
and the lamp will blink twice 4 times.
•
To re-enable the function, press
the
ON/OFF
button and hold it for 6
seconds. The unit will beep twice and
the lamp will blink 4 times.
Type1
ON/OFF
Type2
ON/OFF
NOTE
•
The feature may be changed according
to the type of model.
•
If you press and hold the
ON/OFF
button
for 3 – 5 seconds, instead of 6 seconds,
the unit will switch to the test operation.
In the test operation, the unit blows out
strong cooling air for 18 minutes and then
returns to factory default settings.
Using the Mode Function
This function allows you to select the
desired function.
Cooling Only Model
Cooling Mode
Auto Operation(AI) Mode
Dehumidification Mode
Fan Mode
Cooling & Heating Model
Cooling Mode
Auto Changeover Mode
Dehumidification Mode
Heating Mode
Fan Mode
Cooling Mode
1
Turn the appliance on.
2
Press
Mode
button repeatedly to select
the Cooling Mode.
•
is displayed on the display screen.
3
Press or button to set the desired
temperature.