background image

- 8 -

Copyright ©2017 LG Electronics. Inc. All right reserved.
Only for training and service purposes

LGE Internal Use Only

CN-INV_L_2 (BR)

CN_IN_L_1

CN_IN_N1

CN_F.G

CN-INV_N_2 (BL)

CN2

CN1

Noise Filter

Summary of Contents for A5UW36GFH0

Page 1: ... read this manual carefully before operating your set and retain it for future reference E View Multi Air Conditioner A5UW36GFH0 LMU360HHV A6UW42GFH0 LMU420HHV P NO MFL67452452 SERVICE MANUAL AIR CONDITIONER ...

Page 2: ...ower and Communication Cable Included Earth Outdoor BD Unit No x AWG 4C x 16 4C x 16 Combination Sum of Indoor Units Capacity Max kBth h 48 56 Number of Indoor Units Max EA 5 6 Number of BD Units Max EA 2 2 Casing Color Warm Gray Warm Gray Dimensions W x H x D mm 950 x 1 380 x 330 950 x 1 380 x 330 W x H x D inch 37 13 32 x 54 11 32 x 13 37 13 32 x 54 11 32 x 13 New Weight kg lbs 101 0 222 7 101 0...

Page 3: ...itch X Phase protection X Restart delay 3 minutes O Self diagnosis O Soft start O Test function X Convenience Night Silent Operation O Wiring Error Check O Peak Control O Mode Lock O Forced Cooling Operation Outdoor Unit O Network function Network soluation LGAP O Device A5UW36GFH0 LMU360HHV A6UW42GFH0 LMU420HHV Central Controller AC Ez Simple Controller PQCSZ250S0 AC Ez Touch PACEZA000 AC Smart I...

Page 4: ...mpressor Strainer Strainer Condenser Out Temperature Thermistor Inlet Air Temperature Thermistor Outdoor Unit Ø9 52 Flare Connection Ø19 05 Flare Connection Electronic Expansion Valve Condenser Mid Temperature Thermistor PCB Connector Description CN_MID_BR Cond Middle Pipe CN_DISCHA_BK Discharge Pipe CN_C_PIPE_VI Cond Out Pipe CN_SUCTION_GR Suction Pipe CN_AIR_YL Air CN_H_PRESS_RD Pressure Sensor ...

Page 5: ... 5 Copyright 2017 LG Electronics Inc All right reserved Only for training and service purposes LGE Internal Use Only 4 Wiring Diagrams ...

Page 6: ...nd service purposes LGE Internal Use Only CN_INV CN_LGMV CN_DRYCONTACT CN_CP_N CN_CP_L CN_HEATER_BL CN_4WAY_YL CN_PI_VI_HG_OS_BK CN_POWER_WH CN_C_PIPE_VI CN_AIR_YL CN_H_PRESS_RD CN_SUCTION_GR CN_CNVSS GEN2_BL_J CN_MID_BR CN_EEV_MAIN_VI CN_COM_WH CN_DISCHA_BK GEN1_WH_J MAIN PCB ...

Page 7: ...ght 2017 LG Electronics Inc All right reserved Only for training and service purposes LGE Internal Use Only CN MAIN CN COIL2 CN COIL1 CN INPUT_VOLT_L BR CN INPUT_VOLT_N BL CN W CN V CN U CN FAN2 CN FAN1 INV PCB ...

Page 8: ... 8 Copyright 2017 LG Electronics Inc All right reserved Only for training and service purposes LGE Internal Use Only CN INV_L_2 BR CN_IN_L_1 CN_IN_N1 CN_F G CN INV_N_2 BL CN2 CN1 Noise Filter ...

Page 9: ...649950 261704 W6640A W6640B 268711D 237202 165000 Pressure sensor 561410A 550140B 430410 W4986A W4986B 550140A 268711A W6200 263230A 263230B 263230C 263230D 263230E 561410D 152503 552203A 148000 W52240 552202 552560 552203B Location No Description Sensor Information Housing Color 263230A Thermistor CN_DISCHA_BK Discharge Pipe Black 263230B Thermistor CN_SUCTION_GR Suction Pipe Green 263230C Thermi...

Page 10: ......

Reviews: