![LG A2UC146FA0 Service Manual Download Page 57](http://html.mh-extra.com/html/lg/a2uc146fa0/a2uc146fa0_service-manual_206458057.webp)
Electronic Parts Troubleshooting Guide
Service Manual 57
6. When Vertical Louver does not operate
• Confirm that the Vertical Louver is normally geared with the shaft of
Stepping Motor.
• If the regular torque is detected when rotating the Vertical Louver with
hands
Normal
• Check the connecting condition of CN-U/D Connector
• Check the soldering condition(on PWB) of CN-U/D Connector
If there are no problems after above checks
• Confirm the assembly conditions that are catching and interfering parts
in the rotation radial of the Vertical Louver
Check the operating circuit of the Vertical Louver
• Confirm that there is DC +12V between pin
(RED) of CN-U/D and
GND.