36
Room Air Conditioner
Operation
• Function used to perform the Self Cleaning to prevent the Unit from Fungus and Bad Odors.
• Used after the Shut Down of Cooling Operation to Clean the Evaporator and keep it as fresh for the Next operation.
• During Self Cleaning the Outdoor Unit is Switched off.
• The function is easy to be operated as It is accessed through the Remote Controller.
Auto Cleaning
Auto Changeover
Low Ambient
Comp.
ON
OFF
Setting Step
S-Low
Indoor Fan
ON
Cooling CYCLE
OFF
30 Min
Cleaning
Cooling Start
25 Sec
On
Off
• The air conditioner changes the operation
mode automatically to keep indoor tempera-
ture.
• When room temperature vary over ±2°C with
respect to setting temperature, air condition-
er keeps the room temperature in ±2°C with
respect to setting temperature by auto
change mode.
• If outdoor temperature drops below certain temperature,liquid back is prevented by reducing fan speed.
It can prevent frosting of evaporator and keep cooling operation
• No matter even if the outdoor temperature reaches -10°C.
• You can Cool your room at your desired temperature all your around.
Freq.
- 0
°
C
°
…
Outdoor temp.
Outdoor pipe temp.
0
°
C outdoor fan On/Off
control
°
Comp Freq.
Outdoor fan
On
On
Off
Off
Outdoor temp.:-10
°
C
-5
0
5
10
15
20
25
0
50
100
150
200
Time(Min.)
Temp.(
°
C)
Outdoor fan On/Off control
Cond . temp.
COOLING
Auto
Change
Mode.
Outdoor temp.
Indoor temp.
Outdoor
temp.
30
°
C
20
°
C
10
°
C
+2
°
C
+1
°
C
+0.5
°
C
Set Temp.
-0.5
°
C
-1
°
C
-2
°
C
HEATING