21
ENGLISH
Communication Parameters
Baud rate : 9600 bps (UART)
Data length : 8 bits
Parity : None
Stop bit : 1 bit
Communication code : ASCII code
Use a crossed (reverse) cable.
Command reference list
(Depending upon model)
COMMAND1 COMMAND2
DATA
(Hexadecimal)
COMMAND1 COMMAND2
DATA
(Hexadecimal)
01. Power*
k
a
00 to 01
10.
Sharpness
k
k
00 to 32
02. Aspect
Ratio
k
c
(page 23)
11. OSD
Select
k
l
00 to 01
03. Screen
Mute
k
d
(page 23)
12. Remote
Control Lock
Mode
k
m
00 to 01
04. Volume
Mute
k
e
00 to 01
13. Balance
k
t
00 to 64
05. Volume
Control
k
f
00 to 64
14. Color
(Colour)
Temperature
x
u
00 to 64
06. Contrast
k
g
00 to 64
15. Equalizer j
v
(page 24)
07. Brightness k
h
00 to 64
16. Key
m
c
Key Codes
08. Color/
Colour
k
i
00 to 64
17. Control
Backlight,
Control Panel
Light
m
g
00 to 64
09. Tint
k
j
00 to 64
18. Input
select (Main)
x
b
* Note: During playing or recording media, all commands except Power (ka) and Key (mc) are not executed and
treated as NG. With RS-232C cable, TV can communicate “ka command” in power-on or power-off status. But
with USB-to-Serial converter cable, the command works only if TV is on.
Summary of Contents for 65EV960H
Page 27: ...27 ENGLISH ...
Page 41: ......
Page 84: ...4 5 6 7 480 mm 18 8 inches 18 8 pulgadas po f e ...
Page 85: ...8 9 10 11 ...
Page 86: ...12 13 14 15 16 17 ...
Page 87: ...18 19 ...
Page 88: ...20 21 ...
Page 89: ...1 2 a b 22 23 ...
Page 90: ......
Page 91: ......
Page 92: ...1 2 a b 1 2 a c 3 4 g 1 2 d ...
Page 93: ...1 2 3 4 ...
Page 94: ...1 2 3 1 2 ...
Page 96: ......
Page 97: ... MFL69843802 ...