Established
date
Standard Repair Process Detail Technical Manual
Revised
date
A18
Error
symptom
Content
Check power input voltage and ST-BY 7.8V
B. Power error _No power
SET Model
Power P/N, Name
60UM72
EAY65589001, LGP60T-19U1
MS Level
Range [V]
LED On/Off
MS (0V)
0 ~ 0.25
Off
MS (2V)
1.75 ~ 2.25
On (Home mode)
MS (3V)
2.75 ~ 3.25
On (Store Mode)
Power Check Sequence
1. AC input Check : SK100 (100~240Vac)
2. PWR-ON Check :
- SET On : above 3V
- SET St-by : 0V
3. 13.2V DC Check :
- SET On : 13.2V
- SET St-by : 7.8V
4. MS Level Check : MS
5. LED voltage Check : P801, Pin 1-7
※
Home mode : General Customer
Store mode : use Store
Picture Condition : VIVID (Back light 100)
Min
Max
231.8V
268.4V
all condition meets, Power Board OK.
SK100 (AC input)
P801
P201
Power Board Voltage / Current
For module ‘N’ suffix
ex) KWM
N
LJR
Copyright © 2019 LG Electronics Inc. All rights reserved.
Only for training and service purposes.
Summary of Contents for 60UM6900PUA
Page 93: ......