Control Board
Power Board
Y-Sus Board
Z-Sus Board
Main Board
Making
Revision
PDP TV
Symptom
D. General function defect
Repair Process-Reference data
1.Check connector was inserted properly
on Main board and IR board.
2. Check +3.3V
ST
Voltage at Pin10
3. Check whether appear voltage on multi meter
when operate remote control.
※
Test Condition for case 3
→
Check Point: Pin 1( IR)
→
TV: power on status
→
Multi meter: Select DC 10V
▣
Checking method
Check Remote control IR operation
IR/KEY Board for XXPZ7/90XX
IR Board
A26
A26
-
LED_Power_On
TOUCH_Ver_CHECK
BLUE_LED_ON
IR
GND
KEY1
KEY2
LED-RED
GND
SCL
SDA
+3.3V_ST
+3.3V_Normal/
+5V_MULTI
3.3V Multi
-
2010. 12 . 24
Summary of Contents for 60PZ570T
Page 32: ......
Page 33: ...PDP TV Repair Guide Applicable Model PD12A B C ...